產品中心
- 電力變壓器功能參數測試儀
- LYXC-1000蓄電池活化儀
- LYCS8800一體式變頻線路參數測試儀
- LYYDZ智能耐壓試驗裝置
- LYYB-2000無線型帶電氧化鋅避雷器測試儀
- YDQ充氣式試驗變壓器
- LYXCS-3000電力變壓器消磁儀
- LYBSY-3000交流采樣變送器校驗裝置
- LYSL-1000全智能無線高壓驗電器
- LYLDCS-200漏電保護器測試儀
- LYHL-III智能回路電阻測試儀
- LYXBCS-100泄漏電流試驗裝置
- LYBRZ-V 一體化變壓器繞組變形測試儀
- LYHL-V手持式回路電阻測試儀
- LYZBC-2000變壓器直流電阻變比測試儀
- LYSL-V-4000A三相大電流溫升試驗裝置
- 電容電感測試儀
- LYZKS8000變壓器特性綜合試驗臺
- LYZZC9310手持式直流電阻測試儀
- LYZZC-III直流電阻測試儀(1-50A)
- LYZZC-3310Z三通道助磁直流電阻測試儀(10A-60A)
- LYBBC-2000變壓器變比組別測試儀
- LYBBC-V手持式變壓器變比組別測試儀
- LYBR6000變壓器容量及損耗參數測試儀
- LYBYK4000變壓器有載開關測試儀
- LYBDS4000變壓器參數測試儀
- LYJS9000F變頻抗干擾介質損耗測試儀
- LYPCD3500便攜式在線式局放巡檢儀
- LYPCD3000手持式局放巡檢儀
- LYPCD4000在線式局放巡檢儀
- LYPCD-6000局部放電在線監測系統
- LYSFQ大功率倍頻機組耐壓試驗裝置
- LYRZ-A\B\C變壓器繞組變形測試儀
- LYBJD-V變壓器鐵芯接地電流測試儀
聯系我們
電話:021-56774665 地址:上海市靜安區汶水路8號(導航科技園)
郵編:200072
產品中心
漏電保護器動作特性測試儀
一(yi).LYLDCS-200漏電保護器動作特性測試儀?簡(jian)介
專為現(xian)場在線(xian)測試(shi)各種(zhong)漏(lou)電(dian)(dian)(dian)(dian)保護(hu)器(qi)的漏(lou)電(dian)(dian)(dian)(dian)動(dong)(dong)作電(dian)(dian)(dian)(dian)流、漏(lou)電(dian)(dian)(dian)(dian)不(bu)動(dong)(dong)作電(dian)(dian)(dian)(dian)流、以及漏(lou)電(dian)(dian)(dian)(dian)動(dong)(dong)作時(shi)間,測試(shi)電(dian)(dian)(dian)(dian)流從0~500mA分十檔(dang)(15、30、50、75、100、150、200、250、300、500mA),測試(shi)漏(lou)電(dian)(dian)(dian)(dian)流動(dong)(dong)作時(shi)間量程(cheng)為0~999ms,采用128dots×64dotsLCD顯示,方便(bian)直觀。儀表精度高、體(ti)積小、重(zhong)量輕(qing)、外觀精致,便(bian)于攜(xie)帶,是各種漏電(dian)保護器現場或室(shi)內檢測的理想工具。
二.LYLDCS-200漏電保護器動作特性測試儀??電氣符號
三.技術規(gui)格
功 能 | 測(ce)試各種漏電(dian)保(bao)護(hu)器的漏電(dian)動(dong)(dong)作(zuo)電(dian)流、漏電(dian)不動(dong)(dong)作(zuo)電(dian)流、漏電(dian)動(dong)(dong)作(zuo)時間 |
電(dian) 源 | DC6V 堿性(xing)干電(dian)池(chi) LR6 1.5V×4 |
測試(shi)線路電壓 | AC 250V以下 |
額定電壓 | AC 220V |
漏電(dian)電(dian)流檔位 | 15、30、50、75、100、150、200、250、300、500mA |
測試漏電動作時間量程 | 0~999ms |
漏(lou)電(dian)動作時(shi)間顯示精度 | ±0.5% |
檔(dang)位(wei)電流(liu)精度 | ±1.0% |
失效信(xin)息指(zhi)示 | LCD顯示“fault”失效信(xin)息指(zhi)示,可能測(ce)試的額定(ding)動(dong)作(zuo)電流檔位太小或漏電保(bao)護(hu)器有故障 |
測試線長 | 1.8m |
測試模式(shi) | 手動或(huo)自動 |
顯示(shi)模(mo)式 | LCD:128dots×64dots |
儀表尺(chi)寸 | 170mm×75mm×30mm |
儀表質量 | 290g(含電池);總質量:350g(含包裝) |
LCD尺寸 | 顯(xian)示(shi)域(yu):44mm×27mm |
電(dian)池電(dian)壓 | 當電池電壓降到4.8V時,電池電壓低符號顯示,提醒更換電池。此時測量的數據同樣是準確的。 |
工作電(dian)流 | 40mA Max |
工作溫濕度(du) | -10℃~40℃;80%rh以下 |
存放溫濕(shi)度 | -10℃~60℃;70%rh以下 |
絕緣耐(nai)壓 | 100MΩ或(huo)更大(da), AC2kV/rms(外殼(ke)與螺絲之(zhi)間) |
適(shi)合(he)安規 | IEC1010-1、IEC1010-2-032、污(wu)染等級2、CAT Ⅲ(600V) IEC61326(EMC標準) |
四.結(jie)構
1.N接(jie)口(kou)(接(jie)地(di)線)
2.L接口(kou)(接火線)
3.LCD
4.AT自(zi)動(dong)鍵
5.RANGE+鍵(檔位(wei)加大)
6.MT手(shou)動鍵(jian)
7.RANGE-鍵(檔位減(jian)小)
8.RESET復位(wei)鍵
9.POWER電源鍵(開(kai)關機(ji))
10.鱷魚夾測試(shi)線
11.表筆測試線
12.插座測試(shi)線
五.基本操作
1.開關(guan)機
按POWER鍵開(kai)機(ji),LCD顯(xian)示,若(ruo)開(kai)機(ji)后(hou)LCD顯(xian)示較暗,可能電池電壓不(bu)足,請更換(huan)電池。再按POWER關機(ji)。儀表開(kai)機(ji)5分鐘后(hou)會自動(dong)關機(ji)。
2.手(shou)動(dong)/自動(dong)切換
本儀(yi)表具有手動(dong)(MT)、自動(dong)(AT)測(ce)(ce)試模(mo)式(shi)(shi)(shi)。按“MT”鍵(jian)和“AT”鍵(jian)可以切換(huan)“手動(dong)/自動(dong)”模(mo)式(shi)(shi)(shi),開機(ji)后儀(yi)表默(mo)認為進入手動(dong)(MT)測(ce)(ce)試模(mo)式(shi)(shi)(shi),手動(dong)模(mo)式(shi)(shi)(shi)LCD的左上角顯示(shi)“MT”符號。自動(dong)模(mo)式(shi)(shi)(shi)LCD左上角顯示(shi)“AT”符號。
自(zi)動(dong)模式(shi)測(ce)試時,先(xian)從*低檔15mA額定動(dong)作電(dian)(dian)(dian)流(liu)(liu)(liu)測(ce)試,若(ruo)漏(lou)(lou)電(dian)(dian)(dian)保護器(qi)不跳閘(zha)(zha),2秒鐘后儀表自(zi)動(dong)加大(da)一檔額定動(dong)作電(dian)(dian)(dian)流(liu)(liu)(liu)測(ce)試,若(ruo)漏(lou)(lou)電(dian)(dian)(dian)保護器(qi)還(huan)是(shi)(shi)不跳閘(zha)(zha),再(zai)過(guo)2秒鐘后繼續加大(da)一檔額定動(dong)作電(dian)(dian)(dian)流(liu)(liu)(liu)測(ce)試,直道跳閘(zha)(zha)分斷(duan)為止(zhi),此時儀表LCD下(xia)方所指示的電(dian)(dian)(dian)流(liu)(liu)(liu)檔位(wei)就是(shi)(shi)漏(lou)(lou)電(dian)(dian)(dian)保護器(qi)的實際(ji)漏(lou)(lou)電(dian)(dian)(dian)動(dong)作電(dian)(dian)(dian)流(liu)(liu)(liu)值,顯示的時間(jian)就是(shi)(shi)其漏(lou)(lou)電(dian)(dian)(dian)動(dong)作時間(jian)值。
3.額(e)定動(dong)作電流檔位切換(huan)
本儀表(biao)額定動作(zuo)電流從0~500mA分(fen)為十檔:15mA、30mA、50mA、75mA、100mA、150mA、200mA、250mA、300mA、500mA檔。按“RANGE-”鍵或“RANGE+”鍵可以(yi)切換檔位(wei),LCD下方指示測試所在的檔位(wei)。儀表(biao)開機后默認(ren)以(yi)*低15mA檔開始測試。
4.復位(wei)
每次測試后(hou),按“RESET”鍵復位(wei),漏電(dian)動作時間清零,可進行再次測試。
5.測試(shi)
測試前需先拆開被測漏電(dian)(dian)保(bao)護器的負載(zai)引線,避(bi)免損壞負載(zai)端設備。再查(cha)看被測試漏電(dian)(dian)保(bao)護器的銘牌標(biao)定值,根據銘牌標(biao)定值確定漏電(dian)(dian)電(dian)(dian)流(liu)(liu)檔位。(一般戶內型單相二(er)線式的漏電(dian)(dian)保(bao)護器的額定動(dong)作電(dian)(dian)流(liu)(liu)為30mA,額定不動(dong)作電(dian)(dian)流(liu)(liu)為15mA,分(fen)斷(duan)時間(jian)≤0.1s,即≤100ms)。
儀表(biao)(biao)開機,先選擇測試模式(shi)和額定漏(lou)電(dian)動作電(dian)流檔位,儀表(biao)(biao)開機默認為(wei)手(shou)動(MT)測試模式(shi)。接線參見下(xia)圖。
接(jie)線(xian)一:黑色鱷(e)魚夾測試線(xian)一端(duan)(duan)插(cha)入(ru)儀(yi)表的(de)黑色“N”接(jie)口,另一端(duan)(duan)鱷(e)魚夾夾到被(bei)測試的(de)漏(lou)電保(bao)護器的(de)地線(xian)樁上;紅色表筆測試線(xian)一端(duan)(duan)插(cha)入(ru)儀(yi)表的(de)紅色“L”接(jie)口,另一端(duan)(duan)表筆去觸碰漏(lou)電保(bao)護器輸出端(duan)(duan)(下端(duan)(duan))的(de)火線(xian)進行測試。
接(jie)線(xian)二(er):插(cha)(cha)(cha)座(zuo)測(ce)(ce)試線(xian)的(de)黑(hei)色插(cha)(cha)(cha)頭(tou)插(cha)(cha)(cha)入儀表的(de)“N”接(jie)口,紅色插(cha)(cha)(cha)頭(tou)插(cha)(cha)(cha)入儀表的(de)“L”接(jie)口,三(san)腳插(cha)(cha)(cha)頭(tou)插(cha)(cha)(cha)入或觸碰(peng)插(cha)(cha)(cha)座(zuo)進行測(ce)(ce)試。
此時,性能正(zheng)常的漏(lou)電(dian)(dian)保護器(qi)(qi)(qi)會跳(tiao)閘(zha)分(fen)(fen)斷(duan),儀表LCD顯示(shi)被測(ce)漏(lou)電(dian)(dian)保護器(qi)(qi)(qi)的分(fen)(fen)斷(duan)時間值,如“075 ms”,如果漏(lou)電(dian)(dian)保護器(qi)(qi)(qi)不跳(tiao)閘(zha),LCD顯示(shi)“fault”失效信息,可能測(ce)試的額(e)定動作電(dian)(dian)流檔位太小或(huo)漏(lou)電(dian)(dian)保護器(qi)(qi)(qi)有故障。按(an)“RESET”鍵復位,清理(li)前次(ci)測(ce)試值,可進行(xing)再次(ci)測(ce)試。
六.電池更換
1.當主機電池電壓降到4.8V時,儀表顯示“”符號,表示電池電量不足,請更換電池。
2.按POWER鍵關(guan)機(ji)(ji)(ji),確認(ren)儀表處于關(guan)機(ji)(ji)(ji)狀態,打開(kai)電池(chi)(chi)(chi)蓋板(ban),換上全新合格的(de)電池(chi)(chi)(chi),特別注意(yi)電池(chi)(chi)(chi)規(gui)格極性,蓋好(hao)電池(chi)(chi)(chi)蓋板(ban),再開(kai)機(ji)(ji)(ji)確認(ren)是(shi)否完成電池(chi)(chi)(chi)更換。(如圖):
七.配(pei)置清單
主機 | 1臺 |
掛包 | 1個 |
表筆測試線 | 1條 |
鱷魚夾測試線 | 1條 |
插座測試線 | 1條 |
包裝盒 | 1個 |
堿性干電池(AAA 1.5V) | 4節 |
用戶手冊、保修卡、合格證 | 1份
|