抗干擾介損儀

發(fa)布時(shi)間(jian): 點擊量:723
抗干擾介損儀
 

一、LYJS9000E抗干擾介損儀概述

介損測(ce)量(liang)(liang)是(shi)絕緣(yuan)(yuan)試驗(yan)中很基本的(de)方(fang)法(fa),可以有效地發(fa)現(xian)電(dian)(dian)(dian)(dian)(dian)器(qi)設備(bei)絕緣(yuan)(yuan)的(de)整體受潮劣化(hua)變(bian)質(zhi),以及局部缺陷等。在電(dian)(dian)(dian)(dian)(dian)工制造、電(dian)(dian)(dian)(dian)(dian)氣設備(bei)安裝、交接(jie)和(he)預防性(xing)試驗(yan)中都廣泛(fan)應用(yong)(yong)。變(bian)壓(ya)器(qi)、互感器(qi)、電(dian)(dian)(dian)(dian)(dian)抗器(qi)、電(dian)(dian)(dian)(dian)(dian)容(rong)(rong)器(qi)以及套管、避雷(lei)器(qi)等介損的(de)測(ce)量(liang)(liang)是(shi)衡量(liang)(liang)其(qi)絕緣(yuan)(yuan)性(xing)能的(de)基本方(fang)法(fa)。突破了傳統的(de)電(dian)(dian)(dian)(dian)(dian)橋測(ce)量(liang)(liang)方(fang)式,采(cai)用(yong)(yong)變(bian)頻(pin)電(dian)(dian)(dian)(dian)(dian)源技術,利用(yong)(yong)單片機、和(he)現(xian)代(dai)化(hua)電(dian)(dian)(dian)(dian)(dian)子技術進行自(zi)(zi)動(dong)頻(pin)率變(bian)換(huan)、模/數轉換(huan)和(he)數據運算;達到抗干擾能力強、測(ce)試速度(du)(du)快、精度(du)(du)高、全自(zi)(zi)動(dong)數字化(hua)、操作簡便;電(dian)(dian)(dian)(dian)(dian)源采(cai)用(yong)(yong)大功率開關電(dian)(dian)(dian)(dian)(dian)源,輸(shu)出45Hz和(he)55Hz純正弦波,自(zi)(zi)動(dong)加(jia)壓(ya),可提供高10千(qian)伏的(de)電(dian)(dian)(dian)(dian)(dian)壓(ya);自(zi)(zi)動(dong)濾除50Hz干擾,適(shi)(shi)用(yong)(yong)于(yu)變(bian)電(dian)(dian)(dian)(dian)(dian)站等電(dian)(dian)(dian)(dian)(dian)磁干擾大的(de)現(xian)場測(ce)試。廣泛(fan)適(shi)(shi)用(yong)(yong)于(yu)電(dian)(dian)(dian)(dian)(dian)力行業中變(bian)壓(ya)器(qi)、互感器(qi)、套管、電(dian)(dian)(dian)(dian)(dian)容(rong)(rong)器(qi)、避雷(lei)器(qi)等設備(bei)的(de)介損測(ce)量(liang)(liang)。

二、LYJS9000E抗干擾介損儀安全(quan)措施

1、使用本儀器(qi)前(qian)一(yi)定要認真(zhen)閱(yue)讀本手(shou)冊。

2、儀器的操作(zuo)者應具(ju)備(bei)(bei)一般(ban)電(dian)氣設備(bei)(bei)或儀器的使用常識。

3、本儀器戶(hu)內外均可使用,但應(ying)避開雨淋、腐蝕(shi)氣體、塵埃(ai)過(guo)濃、高溫、陽光直射等場所使用。

4、儀(yi)表應(ying)避免劇烈(lie)振動。

5、對儀器的(de)維修、護理和(he)調整應由專業(ye)人員進(jin)行。

6、在任(ren)何接線之前(qian)必(bi)須用接地電纜(lan)把儀(yi)器接地端(duan)子與(yu)大地可(ke)靠(kao)連(lian)接起來(lai)。

7、由于測(ce)試(shi)設備產(chan)生高(gao)電(dian)壓(ya)(ya),所以測(ce)試(shi)人(ren)員必須(xu)(xu)*嚴格遵守安(an)全操(cao)作(zuo)規程,防止他(ta)人(ren)接觸高(gao)壓(ya)(ya)部件和電(dian)路。直接從(cong)事測(ce)試(shi)的人(ren)員必須(xu)(xu)*了解高(gao)壓(ya)(ya)測(ce)試(shi)線(xian)路,及儀器(qi)操(cao)作(zuo)要點。非從(cong)事測(ce)試(shi)人(ren)員必須(xu)(xu)遠離高(gao)壓(ya)(ya)測(ce)試(shi)區,測(ce)試(shi)區必須(xu)(xu)用柵欄或(huo)繩索、警視牌(pai)等清楚表示出來。

8、儀器的調整維修(xiu)和(he)維護,必(bi)須(xu)在不(bu)加(jia)電(dian)情況下進行(xing),如果必(bi)須(xu)加(jia)電(dian),則(ze)操作(zuo)者必(bi)須(xu)非(fei)常熟(shu)悉(xi)本儀器高壓危險(xian)部(bu)件。

9、保險(xian)(xian)管損壞時(shi),必須(xu)確(que)保更換同樣(yang)的保險(xian)(xian),禁止更換不同型號(hao)保險(xian)(xian)或將保險(xian)(xian)直(zhi)接(jie)短路使用。

10、儀(yi)器出現故障(zhang)時,關閉電源開關,等(deng)待(dai)一分鐘之(zhi)后再檢查。

三、可測試參數

儀器可測(ce)量下(xia)列參數并數字(zi)顯示:

被(bei)測試品的電容量值CX,以pF或nF為單位,1nF=1000pF。

被測(ce)試品的介質損耗(hao)值tgδ,以%顯示。

四、性能特點

1、儀器采用(yong)復數電流(liu)法,測(ce)(ce)量電容、介質損耗(hao)及其它參數。測(ce)(ce)試結果精度高,便(bian)于實現自動化測(ce)(ce)量。

2、儀器采用了變頻(pin)技術來消除現場50Hz工頻(pin)干擾,即使在強電磁干擾的(de)環境下也能測得可靠(kao)的(de)數(shu)據。

3、儀器采用大屏幕液晶顯示(shi)器,測(ce)試過(guo)程通過(guo)漢字菜(cai)單提示(shi)既直觀(guan)又便(bian)于操作。

4、儀器操作簡便,測量過(guo)程由微處理(li)器控(kong)制,只要(yao)選(xuan)擇好合(he)適的(de)測量方(fang)式,數據的(de)測量就可在微處理(li)器控(kong)制下自動完成。

5、一體化機型,內(nei)附標準電容和高壓電源,便(bian)于現(xian)場(chang)測(ce)試,減少現(xian)場(chang)接線(xian)。

6、儀器測(ce)量(liang)(liang)準確度高(gao),可滿(man)足油(you)介損(sun)測(ce)量(liang)(liang)要求,因此只需(xu)配備標準油(you)杯,和測(ce)試線即(ji)可實(shi)現油(you)介損(sun)測(ce)量(liang)(liang)。

7、設CVT測試功能,可實現CVT的(de)自激(ji)法測試,無需外(wai)置附件,只(zhi)需一次測量,C1,C2的(de)電容和介損全部測出(chu)。

8、反接線測試(shi)采用ivddv技(ji)術,消除了以往反接線數據不(bu)穩(wen)定的現(xian)象。

9、具有反接線低壓屏(ping)蔽功(gong)能,在220kV CVT 母線接地情況下,對C11 可(ke)進行(xing)不拆線10kV 反接線介損(sun)測量

10、具有測量高電壓(ya)介損(sun)功能(neng),能(neng)夠使用高壓(ya)變壓(ya)器或串聯諧振進行超過(guo)10kV電壓(ya)的(de)介損(sun)試驗。

12、接(jie)(jie)地(di)保(bao)護(hu)功能(neng),當儀器(qi)不接(jie)(jie)地(di)線或接(jie)(jie)地(di)不良時(shi),儀器(qi)不進入正常程序(xu),不輸(shu)出高壓。過流保(bao)護(hu)功能(neng),在試品短路或擊穿時(shi)儀器(qi)不受損壞(huai)。

13、觸電(dian)保護(hu)功(gong)能(neng),當(dang)儀(yi)器操作(zuo)人員(yuan)不小(xiao)心觸電(dian)時候,儀(yi)器會立即切斷高(gao)壓,保障試驗人員(yuan)的安全.

五、技(ji)術指(zhi)標

準確度:   Cx:     ±(讀數(shu)×1%+1pF)

tgδ:  ±(讀數×1%+0.00040)

干擾(rao)指標:  變頻抗干擾,在200%干擾下仍(reng)能達到上述準確度

電容量范圍:  內施高(gao)壓(ya): 3pF~60000pF/10kV    60pF~1μF/0.5kV

外施(shi)高壓: 3pF~1.5μF/10kV      60pF~30μF/0.5kV

分辨率:  高0.001pF,4位有效數(shu)字

tgδ范圍:    不限,分(fen)辨率0.001%,電(dian)容、電(dian)感、電(dian)阻三種試品自(zi)動識別。

試驗電(dian)流范(fan)圍(wei):10μA~1A

內施高壓: 設(she)定電壓范圍:0.5~10kV

大輸出電流(liu):200mA

升降壓方(fang)式:連續平滑(hua)調節

試(shi)驗頻(pin)(pin)率(lv): 45、50、55、60、65Hz單頻(pin)(pin)

45/55Hz、55/65Hz、47.5/52.5Hz自動雙變頻

頻率精度(du): ±0.01Hz

外施高(gao)壓: 正接線時大試(shi)驗電流(liu)1A,工頻或變頻40-70Hz

反接線時大試驗電流10kV/1A,工頻或變頻40-70Hz

CVT自激法低壓輸出:輸出電壓3~50V,輸出電流3~30A

CVT變比測(ce)量:

變比(bi)測(ce)量精度(du):±讀數×1%    ; 變比(bi)測(ce)量范圍(wei):10~99999

相(xiang)位(wei)測量精度(du):±0.1°    ;       相(xiang)位(wei)測量范(fan)圍:0~359.9°

測量(liang)時(shi)間: 約40s,與(yu)測量方式有關(guan)

輸(shu)入電(dian)源: 180V~270VAC,50Hz±1%,市電(dian)或(huo)發電(dian)機供電(dian)

計算機接(jie)口:  標準RS232接口

打印機:      煒煌A7熱敏微(wei)型打印機

環(huan)境溫度(du): -10℃~50℃

相對濕度: <90%

外(wai)形尺寸:460×360×350mm

儀器重(zhong)量(liang):28kg

六、測(ce)量方式(shi)及原理

按被測試品是否(fou)接地分兩(liang)種(zhong)測量方(fang)式,即正接線測量方(fang)式和反接線測量方(fang)式。兩(liang)種(zhong)測量方(fang)式的原理如圖一(yi)所示:

在高(gao)壓電源的10kV側,高(gao)壓分兩路,一路給(gei)機(ji)內標準電容CN,此電容介損非(fei)常小(xiao),可以(yi)認為(wei)介損為(wei)零,即為(wei)純容性(xing)電流,此電流ICN 可做為容性電(dian)流(liu)基準。在(zai)Cx試品(pin)一(yi)側,試品(pin)電(dian)流(liu)Icx通過采樣電(dian)阻(zu)R采入機內,此Icx可(ke)(ke)分(fen)解成水平分(fen)量和垂直分(fen)量見圖二所示(shi),通過計算水平分(fen)量與(yu)垂直分(fen)量的(de)比值(zhi)即可(ke)(ke)得到tgδ值(zhi)。

在(zai)圖(tu)一(a)中Cx為非(fei)接(jie)地試品(pin),試品(pin)電流Icx從試品(pin)末端進入采樣(yang)電阻R,得到全(quan)電流值,在(zai)圖(tu)一(b)中Cx為接(jie)地試品(pin),機內Cx端直接(jie)接(jie)地,電流Icx從試品(pin)高壓端到機內采樣(yang)電阻取得全(quan)電流值。

七(qi)、常見(jian)設(she)備(bei)的接線方(fang)法

1.儀器(qi)引(yin)出端子說明:

HV ——  儀器的測(ce)量引(yin)線高壓端(帶(dai)危險電壓) 。

CX ——  正接線時試品(pin)電流(liu)輸入(ru)端。

——  儀器(qi)的接(jie)地端,使用時與大地可靠相接(jie)

2.參(can)考接線

2.1正(zheng)接線(xian)、內標(biao)準(zhun)電(dian)容、內高壓(ya)(常規正(zheng)接線(xian)):

2.2反接線、內標準電容、內高壓(常規反接線)

2.3正接線、外標準電容、內高壓:

2.4反接線(xian)、外標準電容(rong)、內高(gao)壓:

2.5正接線、內標準電容、外高(gao)壓(ya):

2.6反接線、內(nei)標(biao)準電容、外高壓:

2.7正接線、外標準電容、外高壓(高電壓介損):

2.8反接線、外(wai)(wai)標準電容、外(wai)(wai)高壓:

2.9  CVT自激法測量(liang):

CVT自激法可按下圖接線。如果C1是單節電容,母線不能接地;如(ru)果C1是(shi)多節電容,母線(xian)可接地,C11C12可用常規正(zheng)反(fan)接線測量,C13C2用自激法測(ce)量。

CVT自激法測量(liang)中(zhong),儀器先(xian)測量(liang)C1,然(ran)后自動倒(dao)線測量(liang)C2,并自動校準分壓影(ying)響。

應(ying)注意,高(gao)壓線應(ying)懸空不能接(jie)觸(chu)地面(mian),否(fou)則其對地附加介(jie)損會引起誤(wu)差,可用細電纜(lan)連接(jie)高(gao)壓插座與(yu)CVT試品(pin)并吊(diao)起。強烈(lie)建議使用高壓插座使用的高壓線用黑色(se)Cx線。

2.10 CVT變比(bi)測(ce)試

儀器高壓(ya)線的(de)芯(xin)線紅夾(jia)(jia)子接(jie)CVT的(de)上端,母線拆(chai)地。CVT下端接(jie)地,低壓(ya)線紅黑夾(jia)(jia)子接(jie)二(er)次(ci)繞組,注意:如果測(ce)試(shi)角度接(jie)近180度,應將紅黑夾(jia)(jia)子顛倒。

3.附加功能

3.1光標(biao)在 電壓:10kV上面時候,按“確認(ren)”鍵在儀器屏幕的(de)左下角會出現(xian)圖標,代表測(ce)試結束(shu)自(zi)動打印(yin)。如果再按(an)確(que)認鍵,圖標消失,代表測(ce)試結束(shu)必須手動才能打印(yin)。

3.2光標在(zai) 反(fan)接(jie) 上面時候,在反(fan)接線,內Cn,內Un,情(qing)況下,按確認鍵在儀器(qi)屏幕右(you)下角會出現圖標,代表(biao)反接(jie)線低壓(ya)屏(ping)蔽測(ce)試。如果(guo)再按確(que)認鍵,圖標消(xiao)失(shi),代表(biao)取消(xiao)反接(jie)線低壓(ya)屏(ping)蔽。

反接線低壓(ya)屏蔽功能,一(yi)次接線可同時測(ce)出C1和(he)C2的電容(rong)量(liang)和(he)介損在反接線、內標(biao)準和(he)內高壓(ya)方式,光(guang)標(biao)移到“反(fan)接”處,按“確認”右下角顯示“M”。

打開反(fan)接(jie)線(xian)低壓屏蔽,可(ke)在上(shang)端電容(rong)C1不(bu)拆母線(xian)的情況(kuang)下(xia),對(dui)其進行(xing)不(bu)拆線(xian)10kV反(fan)接(jie)線(xian)介損(sun)測(ce)量。如(ru)下(xia)圖所(suo)示:母線(xian)掛(gua)地線(xian),C1上(shang)端不(bu)拆線(xian),C1下(xia)端接(jie)高壓線(xian)芯線(xian),C2末端接(jie)Cx芯線(xian)。儀器采用反(fan)接(jie)線(xian)/10kV/M測(ce)量方式,可(ke)同(tong)時測(ce)出C11和下(xia)端屏蔽部分(fen)的電容(rong)量和介損(sun)值。

3.3光標在(zai) 接(jie) 上面時候(hou),按確認鍵則測試打印機,換紙。

3.4光標在 啟動 上面時候,按減小鍵則代表取(qu)出存(cun)儲的數據。

3.5測試完畢,如果按減(jian)小鍵,則(ze)代(dai)表存儲(chu)測試的數據

八(ba)、功能簡介

儀器面板見圖九(jiu)所(suo)示:

1.打印(yin)機——打印(yin)測(ce)量數據。

2.顯(xian)示器&mdash;—128×64點陣(zhen)液(ye)晶顯(xian)示器,顯(xian)示菜單和各(ge)種提示信息(xi)及(ji)測(ce)量結果(guo)。

3.鍵(jian)——選擇菜單項,被選中項反(fan)白字體(ti)顯示。

4.▲  鍵——修改(gai)菜單內容(rong),采用循環滾動(dong)方式。

5.▼ 鍵——修改菜(cai)單(dan)內容(rong),采用循環滾(gun)動方(fang)式。

6.確認鍵——在(zai)“測試”選項(xiang)上按此鍵進入測試狀(zhuang)態。

7.電(dian)源開(kai)關&mdash;&mdash;整(zheng)機電(dian)源的(de)開(kai)啟和關閉。

8.電(dian)源座—&mdash;交流220V±10%,50±1Hz電(dian)源輸入口,帶保險倉(cang)。

9.自激法電(dian)流輸出端(duan)——測量CVT的端(duan)子(zi)。

10.地——為(wei)接地線(xian)接線(xian)端子。

11.CX插座&mdash;—是試品信號的測量輸入端(duan),正接線時由低(di)壓(ya)電(dian)纜連接,此(ci)(ci)電(dian)纜單層屏蔽帶特制鱷魚(yu)夾,長8m,接試品低(di)端(duan)。反接線時此(ci)(ci)端(duan)空(kong)置(zhi)。

12.CN插座(zuo)——是外標準(zhun)電(dian)容信號的測量輸入端,使用內標準(zhun)時此端空(kong)置。

13.HV插座(zuo)——高壓(ya)引(yin)出端子,由高壓(ya)電纜連(lian)接,接試品高壓(ya)端。輸出10kv高壓(ya)。

14.RS-232接口,用來連接電腦,上傳數據(ju)。

15.接地,可以(yi)懸(xuan)空

九(jiu)、儀(yi)器(qi)操(cao)作步(bu)驟

1.測量前準備(bei):

1)用接地(di)線一端接儀器的(de)接地(di)柱,另一端接可靠的(de)大地(di),保證儀器外殼(ke)處(chu)在(zai)地(di)電位上。

2)正接線時:將高(gao)壓電纜(lan)插頭插入(ru)后門HV插(cha)座中,將另一端(duan)的紅色大鉗子夾到被(bei)測試品的引線上,黑(hei)色小鉗子懸空或夾在紅色大鉗子上。將CX低壓(ya)電纜插入CX插座中,另一端的(de)紅(hong)色夾子(zi)夾試品的(de)低端,黑(hei)色夾子(zi)懸空或接屏蔽(bi)裝置。

3)反接線時:將高(gao)壓電纜插頭(tou)插入后門HV插座中,將另一端的紅色大鉗子(zi)夾到被(bei)測試品的引(yin)線上,紅色小鉗子(zi)懸空或接屏蔽裝置。Cx插座不

2.打開電(dian)源開關,儀器進行自(zi)檢,若(ruo)自(zi)檢良好,液晶屏顯(xian)示中文主菜(cai)單如(ru)

圖(tu)十所(suo)示。

3.菜單選擇:

1)按(an)鍵(jian)可移動光(guang)標至各菜單項(xiang),并(bing)循環指示。被選中項(xiang)反白字體顯示。選擇(ze)鍵(jian)的流程見圖十一所示。

2)在(zai)光標當前所示(shi)項目,按▼ ▲鍵鍵可(ke)進行該項菜(cai)單的變更,并循環(huan)指示(shi),流程見圖十二所示(shi)。

3)將菜(cai)單(dan)變更至與測試要求相(xiang)對應后即可按選(xuan)擇鍵進行下(xia)個項目的選(xuan)擇。

4、 頻(pin)率:光(guang)標(biao)在頻(pin)率上,按&uarr;↓鍵選擇定(ding)頻(pin)和變頻(pin):

光(guang)標在定頻(pin)上(shang):按(an)住“啟停”鍵(jian)(jian)1s以上(shang)切換到全(quan)頻(pin)率(lv)選擇,按(an)↑↓鍵(jian)(jian)循環(huan)顯示45Hz / 47.5Hz / 50Hz / 52.5Hz / 55Hz / 60Hz / 65Hz

工頻50Hz測量(liang),此設(she)置不能抗干擾,在試(shi)驗(yan)室內(nei)測量(liang)或校(xiao)驗(yan)時(shi)選用(yong)50Hz,“45/47.5/55/52.5/60/65Hz”:為單頻率測量(liang),研(yan)究不同頻率下(xia)介損的(de)變化(hua)時(shi)選用(yong)。

光標在變頻(pin)(pin)上:按住(zhu)“啟停(ting)”鍵1s以上切(qie)換到全頻(pin)(pin)率選擇,按↑&darr;鍵循環顯示5-Hz / 6-Hz / 4-Hz”:

“5-Hz”:為(wei)45/55Hz自(zi)動變頻,適(shi)合50Hz電網工頻干擾(rao)下測量。

“6-Hz”:為55/65Hz自動變頻,適合60Hz電網工頻干擾下(xia)測(ce)量。

&ldquo;4-Hz”:為(wei)47.5/52.5Hz自(zi)動變頻,適合50Hz電網工頻干擾下測量(liang)。

5、測試:當光標在 測試 項目(mu)上時,按確(que)認鍵大約3秒鐘(zhong)開始測(ce)試。測(ce)試過程中顯示的畫面如圖十三(san)(正接線,變頻)所示,當下面的進程到100%時候測(ce)試完畢(bi),然后顯示測(ce)量結果(guo)見(jian)圖(tu)十四所示,此(ci)時光標(biao)指(zhi)示打(da)印機圖(tu)標(biao),按確(que)認鍵打印報(bao)告。測量結果的意(yi)義(yi)如下:

tgδ:試(shi)品的損耗因數tgδ值

CX: 測量的電容(rong)值

V:施加電壓值

I:試(shi)品(pin)流過的(de)電流

F1,F2 : 試驗頻率

打(da)印(yin)結(jie)束后,關閉電源開關,測試完畢。

十、現場試驗注(zhu)意事項

如(ru)果使(shi)用中出現測試數(shu)據明顯不合理,請從以下方面查找(zhao)原因:

1、搭鉤接觸不良

現場測量使用搭鉤(gou)連接試品時,搭鉤(gou)務必(bi)與(yu)試品接觸(chu)良好,否則(ze)接觸(chu)點放電會引(yin)起數(shu)據嚴重(zhong)波動!尤其是引(yin)流(liu)線氧化層(ceng)太(tai)厚,或風吹線擺動,易造成接觸(chu)不(bu)良。

2、接(jie)地接(jie)觸不良

接地不良(liang)會引起儀器(qi)保護或數(shu)據嚴重(zhong)波(bo)動(dong)。應刮凈接地點上的(de)油漆和銹蝕,務必(bi)保證0電阻接地!

3、直接測(ce)量(liang)CVT或末(mo)端(duan)屏(ping)蔽法測(ce)量(liang)電(dian)磁式PT

直接(jie)測(ce)量(liang)CVT的下節耦合電容會出現負(fu)介損,應改用自激法。

用末端屏(ping)蔽法(fa)(fa)測量電磁式PT時,由于(yu)受潮引起“T形網絡(luo)干擾”出現負(fu)介損,吹干下面三裙瓷套和接線(xian)端子盤即可(ke)。也可(ke)改用常規法(fa)(fa)或末端加壓(ya)法(fa)(fa)測量。

4、空氣濕度過大

空氣濕度大(da)使(shi)介損測(ce)量值異(yi)常增大(da)(或減小甚至為負)且(qie)不穩(wen)定,必(bi)要時可加屏蔽環。因(yin)人為加屏蔽環改變了試品(pin)電(dian)場分布,此法有爭議,可參照有關(guan)規程。

5、發電機供電

發電(dian)機(ji)供電(dian)時輸入(ru)頻率不穩定(ding),可采用(yong)定(ding)頻50Hz模式(shi)工作。

6、測試線

由于長(chang)期使(shi)用,易造成(cheng)測試線(xian)隱性斷(duan)路(lu)(lu),或芯線(xian)和(he)屏蔽短路(lu)(lu),或插頭接觸不良(liang),用戶應(ying)經常(chang)維護測試線(xian);

測(ce)試標準電(dian)容(rong)試品時,應使用全屏蔽插(cha)頭連接,以(yi)消除附加(jia)雜(za)散電(dian)容(rong)影(ying)響,否則不(bu)能反映出儀器(qi)精(jing)度;

自(zi)激(ji)法(fa)測(ce)量CVT時,非的高壓線應吊起懸(xuan)空,否則對地附加雜(za)散(san)電容和介損會引(yin)起測(ce)量誤(wu)差。

7、工作模式(shi)選(xuan)擇

接(jie)好(hao)線后請選(xuan)擇正確的測量工作模式(shi)(正、反(fan)和CVT),不(bu)可選(xuan)錯。特別是干(gan)擾(rao)環(huan)境下應選(xuan)用(yong)變頻(pin)抗干(gan)擾(rao)模式(shi)。

8、試(shi)驗(yan)方法影響

由于介損測量受(shou)試驗方法影響較大,應區分是試驗方法誤差還是儀器誤差。出現(xian)問題時可首(shou)先檢查接線(xian),然(ran)后檢查是否為儀器故(gu)障。

9、儀器故(gu)障

用萬用表測量(liang)一下測試(shi)線(xian)是否(fou)斷路,或芯(xin)線(xian)和屏蔽是否(fou)短路;輸入電源220V過高或過低;接地是否(fou)良好(hao)。

用正、反接線測一下標準電容(rong)器或已(yi)知容(rong)量和(he)介(jie)損(sun)的電容(rong)試品,如果(guo)結(jie)果(guo)正確(que),即可判斷儀器沒有問題(ti);

拔下所(suo)有測試(shi)導線,進行空試(shi)升壓,若不能正(zheng)常工作,儀(yi)器可能有故障。

啟(qi)動CVT測(ce)量(liang)后(hou)測(ce)量(liang)低壓(ya)輸(shu)出(chu),應出(chu)現2~5V電(dian)壓(ya),否則儀器(qi)有(you)故障。

十一、 儀器檢定

1、用標準損耗(hao)器檢定

用帶插(cha)頭的屏蔽電纜連(lian)接標(biao)準(zhun)損(sun)耗器。如果不能(neng)保證(zheng)標(biao)準(zhun)損(sun)耗器的精度,應使用比對(dui)法(fa)檢定,建(jian)議用2801電橋或其它精密電橋作比對(dui)標(biao)準(zhun)。儀器應選用“內標(biao)準(zhun)”和“RC串聯試品”,可選擇工(gong)頻 50Hz或定頻50Hz頻率模式。

2、用QSJ3檢(jian)定(ding):使用帶插頭的(de)屏蔽電纜連接QSJ3,選(xuan)擇“正接/ 外(wai)Cn / 外(wai)Un式測量,電流比為Cx∶Cn,Cn可置入(ru)適當值。

3、抗干擾能力(li)

設置一個回路向(xiang)儀(yi)器注入定(ding)量(liang)的干擾電流。

注意:

1)應考(kao)慮(lv)到該回路(lu)可能(neng)成為(wei)試品(pin)的一部分。

2)儀(yi)器啟動后(hou)會使220V供電(dian)電(dian)路帶有測量(liang)頻(pin)率分量(liang),如果(guo)該(gai)頻(pin)率分量(liang)又(you)通過干擾電(dian)流(liu)進(jin)入(ru)儀(yi)器,則(ze)無(wu)法檢驗儀(yi)器的抗干擾能力。

3)不建議用臨近高壓(ya)導(dao)體(ti)施加干擾,因為這樣很容易產生近距離*放電(dian),這種(zhong)放電(dian)電(dian)阻是非線性(xing)的,容易產生同(tong)頻干擾。

十(shi)二、變頻測量討論

1、變(bian)頻測量(liang)

干擾十分嚴(yan)重時(shi),變頻(pin)(pin)測(ce)量能得到準(zhun)確可靠的結果(guo)。例如用55Hz測(ce)量時(shi),測(ce)量系統(tong)只允許(xu)55Hz信號(hao)通過,50Hz干擾信號(hao)被有效(xiao)抑制,原(yuan)因在(zai)于(yu)測(ce)量系統(tong)很容(rong)易區別不同(tong)頻(pin)(pin)率,由下述簡(jian)單(dan)計(ji)算可以說(shuo)明(ming)選頻(pin)(pin)測(ce)量的效(xiao)果(guo):

兩(liang)個頻率相差1倍(bei)的正弦波疊加到一起,高頻的是干擾,幅度為低頻的10倍(bei):

Y=1.234sin(x+5.678°)+12.34sin(2x+87.65°)

在x=0/90/180/270°得到4個測量值(zhi)

Y0=12.4517,Y1= -11.1017,Y2=12.2075,Y3= -13.5576,

計(ji)算(suan)A=Y1-Y3=2.4559,B=Y0-Y2=0.2442,則:φ=tg-1(B/A)=5.678°    V=  A2+B2/2=1.234

這剛(gang)好是低頻部(bu)分的相位和幅度(du),干(gan)擾(rao)被抑制。實(shi)際(ji)波形的測量點(dian)多(duo)達數萬,計算量很大,結果反映(ying)了波形的整(zheng)體特征。

2、頻率和介損的(de)關系

介損有RC串(chuan)聯(lian)和(he)(he)并(bing)聯(lian)兩種理想模(mo)(mo)型(xing):串(chuan)聯(lian)模(mo)(mo)型(xing)tgδ=2πfRC,并(bing)聯(lian)模(mo)(mo)型(xing)tgδ=1/(2πfRC),tgδ分別隨(sui)頻率f成正比(bi)和(he)(he)反(fan)比(bi)。如圖(tu)所(suo)示,f對*正比(bi)和(he)(he)*反(fan)比(bi)兩種模(mo)(mo)型(xing)影響較大。但(dan)實際電容器是(shi)多(duo)種模(mo)(mo)型(xing)交織(zhi)的混(hun)合模(mo)(mo)型(xing),此時f的影響就小。

3、自動(dong)變頻與50Hz等效

儀器采用自動變頻在干擾頻率50Hz兩側(45Hz和55Hz)各測一個點,然后推算50Hz頻率下數據。除多個元件電路的低頻諧振外,單個試品中的介質不可能在低頻引起能量吸收峰,工頻附近介損總是隨頻率單調變化的。因此這種測量方法不會帶來明顯誤差。實際上,平均前的兩個介損值已十分接近,即使不平均也*有參考價值。目前,變頻介損儀已成為介損測量的常規儀器,其優異的抗干擾能力和準確度已經得到認可。

十三、儀器(qi)的裝箱清單

1.主機

一臺

2.高壓電纜

一條

3.低壓(ya)電纜

兩(liang)條(tiao)

4.電(dian)源線

一條

5.地(di)線

一條

6.CVT線

一條

7.5A保(bao)險(xian)管(內置)

兩只(zhi)

8.打(da)印(yin)紙(zhi)

一卷(juan)

9.說明(ming)書

一本

10.出廠試驗報告

一份

11.合格證

一張(zhang)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

一(yi)、概述

介(jie)(jie)損測(ce)量是(shi)絕(jue)緣(yuan)試(shi)驗中(zhong)很基本的(de)(de)方法,可以有(you)效地發現電(dian)(dian)(dian)(dian)器(qi)(qi)設(she)備(bei)絕(jue)緣(yuan)的(de)(de)整體(ti)受潮劣(lie)化(hua)變(bian)質,以及局部缺(que)陷等。在電(dian)(dian)(dian)(dian)工制造、電(dian)(dian)(dian)(dian)氣設(she)備(bei)安裝、交接和(he)預防性試(shi)驗中(zhong)都(dou)廣泛(fan)應用(yong)。變(bian)壓器(qi)(qi)、互(hu)感器(qi)(qi)、電(dian)(dian)(dian)(dian)抗(kang)器(qi)(qi)、電(dian)(dian)(dian)(dian)容器(qi)(qi)以及套管(guan)、避雷器(qi)(qi)等介(jie)(jie)損的(de)(de)測(ce)量是(shi)衡量其絕(jue)緣(yuan)性能的(de)(de)基本方法。LYJS9000F變(bian)頻(pin)介(jie)(jie)質損耗測(ce)試(shi)儀突破了傳統的(de)(de)電(dian)(dian)(dian)(dian)橋測(ce)量方式,采用(yong)變(bian)頻(pin)電(dian)(dian)(dian)(dian)源(yuan)技術(shu),利用(yong)單(dan)片(pian)機(ji)、和(he)現代(dai)化(hua)電(dian)(dian)(dian)(dian)子技術(shu)進行(xing)自(zi)動(dong)(dong)(dong)頻(pin)率(lv)變(bian)換、模(mo)/數轉(zhuan)換和(he)數據運算;達到抗(kang)干(gan)擾能力(li)強、測(ce)試(shi)速度(du)快、精度(du)高、全自(zi)動(dong)(dong)(dong)數字化(hua)、操作簡便;電(dian)(dian)(dian)(dian)源(yuan)采用(yong)大(da)功(gong)率(lv)開(kai)關電(dian)(dian)(dian)(dian)源(yuan),輸出45Hz和(he)55Hz純正弦波(bo),自(zi)動(dong)(dong)(dong)加壓,可提供高10千(qian)伏的(de)(de)電(dian)(dian)(dian)(dian)壓;自(zi)動(dong)(dong)(dong)濾除50Hz干(gan)擾,適(shi)用(yong)于變(bian)電(dian)(dian)(dian)(dian)站(zhan)等電(dian)(dian)(dian)(dian)磁干(gan)擾大(da)的(de)(de)現場測(ce)試(shi)。廣泛(fan)適(shi)用(yong)于電(dian)(dian)(dian)(dian)力(li)行(xing)業(ye)中(zhong)變(bian)壓器(qi)(qi)、互(hu)感器(qi)(qi)、套管(guan)、電(dian)(dian)(dian)(dian)容器(qi)(qi)、避雷器(qi)(qi)等設(she)備(bei)的(de)(de)介(jie)(jie)損測(ce)量。

二、安全措施

1、使用本儀器(qi)前一定要認真(zhen)閱讀本手冊。

2、儀器的(de)(de)操作(zuo)者(zhe)應具備一般(ban)電氣設備或儀器的(de)(de)使用常識。

3、本儀器戶內外均可(ke)使用,但應避開雨淋、腐蝕(shi)氣體(ti)、塵埃過(guo)濃、高溫、陽(yang)光直射等場所使用。

儀(yi)表應避免劇烈振動。

5、對儀器的維修、護理和(he)調整應由(you)專(zhuan)業人員進(jin)行。

6、在任何接(jie)線(xian)之前(qian)必(bi)須用接(jie)地(di)電(dian)纜把(ba)儀器接(jie)地(di)端子(zi)與大(da)地(di)可靠連接(jie)起來。

7、由于測(ce)(ce)試(shi)(shi)(shi)(shi)設備產生(sheng)高(gao)電(dian)壓(ya),所以測(ce)(ce)試(shi)(shi)(shi)(shi)人員必(bi)(bi)須(xu)(xu)*嚴格遵守安全(quan)操(cao)作規程(cheng),防(fang)止他人接觸高(gao)壓(ya)部(bu)件(jian)和(he)電(dian)路(lu)。直接從事(shi)測(ce)(ce)試(shi)(shi)(shi)(shi)的(de)人員必(bi)(bi)須(xu)(xu)*了(le)解高(gao)壓(ya)測(ce)(ce)試(shi)(shi)(shi)(shi)線(xian)路(lu),及儀(yi)器操(cao)作要點。非從事(shi)測(ce)(ce)試(shi)(shi)(shi)(shi)人員必(bi)(bi)須(xu)(xu)遠離高(gao)壓(ya)測(ce)(ce)試(shi)(shi)(shi)(shi)區,測(ce)(ce)試(shi)(shi)(shi)(shi)區必(bi)(bi)須(xu)(xu)用柵欄或(huo)繩(sheng)索、警視牌等(deng)清楚(chu)表示出來。

8、儀器的調整(zheng)維修(xiu)和維護(hu),必須在(zai)不加電情況下進行,如果(guo)必須加電,則操作者必須非常熟悉本儀器高壓危險部件。

9、保險(xian)管損壞時(shi),必須確(que)保更換同樣的(de)保險(xian),禁止更換不同型號(hao)保險(xian)或將保險(xian)直接短路使(shi)用。

儀器出(chu)現(xian)故(gu)障時,關閉電(dian)源開關,等待一分鐘之后再檢查(cha)。

三、可測試參(can)數(shu)

儀器可測量下(xia)列參數并數字顯示:

被測(ce)試品的電容量值CX,以pF或nF為單位,1nF=1000pF。

被測試品的(de)介(jie)質損耗值tgδ,以%顯(xian)示。

四、性能特點(dian)

1、儀器采用復數電流法,測(ce)量(liang)電容、介(jie)質損耗及其(qi)它參數。測(ce)試結果(guo)精度高,便于實(shi)現自(zi)動化(hua)測(ce)量(liang)。

2、儀器采(cai)用了變頻技術來消(xiao)除現場50Hz工(gong)頻干(gan)擾(rao),即(ji)使在強電磁干(gan)擾(rao)的環境(jing)下也能測得可靠的數據。

3、儀器采用大屏(ping)幕(mu)液晶(jing)顯(xian)示器,測試過程通過漢字菜單提(ti)示既(ji)直觀又便于操(cao)作。

4、儀(yi)器(qi)操作簡(jian)便,測量過程由微處理(li)器(qi)控(kong)制,只要選擇(ze)好合適的測量方式,數據的測量就可在微處理(li)器(qi)控(kong)制下自(zi)動完成。

5、一體(ti)(ti)化機型,內附標準電容(rong)和高壓電源,便于(yu)現場(chang)測試,減(jian)少現場(chang)接(jie)線。

6、儀(yi)器測量(liang)(liang)準確度高,可(ke)(ke)滿(man)足油(you)(you)介損測量(liang)(liang)要求,因此(ci)只需(xu)配備(bei)標準油(you)(you)杯,和測試(shi)線(xian)即可(ke)(ke)實現油(you)(you)介損測量(liang)(liang)。

7、設CVT測試(shi)功能,可實現CVT的(de)自激法測試(shi),無需外置附件,只需一次(ci)測量(liang),C1,C2的(de)電容和介損全部(bu)測出。

8、反(fan)接線測(ce)試(shi)采用ivddv技(ji)術,消(xiao)除了以往反(fan)接線數據不穩定的(de)現象(xiang)。

9、具有反接(jie)線(xian)低壓屏(ping)蔽功能,在220kV CVT 母(mu)線(xian)接(jie)地情況下,對(dui)C11 可進行不拆(chai)線(xian)10kV 反接(jie)線(xian)介損測量

10、具有測量高電壓介損功能,能夠使用高壓變壓器或串聯諧振(zhen)進(jin)行超(chao)過10kV電壓的介損試(shi)驗。

12、接(jie)地保護功(gong)能(neng)(neng),當儀器(qi)不(bu)接(jie)地線或接(jie)地不(bu)良(liang)時,儀器(qi)不(bu)進入正常程序,不(bu)輸出高壓。過流(liu)保護功(gong)能(neng)(neng),在試品短路或擊穿時儀器(qi)不(bu)受(shou)損壞(huai)。

13、觸電保護功能(neng),當儀器(qi)操作人員不小心(xin)觸電時候,儀器(qi)會立即(ji)切斷高壓,保障試驗人員的安全.

五、指標

準確度(du):

Cx:±(讀(du)數(shu)×1%+1pF)

tgδ:±(讀數×1%+0.00040)

抗干擾指標:變頻抗干擾,在200%干擾下仍能(neng)達(da)到上述準(zhun)確度

電容量范圍(wei):

內施高(gao)壓:3pF~60000pF/10kV    60pF~1μF/0.5kV

外施高壓:3pF~1.5μF/10kV     60pF~30μF/0.5kV

分辨率:高0.001pF,4位有效數字

tgδ范圍:不限,分辨率0.001%,電容、電感、電阻(zu)三種(zhong)試品自動識(shi)別。

試(shi)驗電流范(fan)圍:10μA~1A

內施(shi)高壓:設定電(dian)壓范(fan)圍(wei):0.5~10kV

大輸出電流:200mA

升降壓方式:連續(xu)平滑調節

試(shi)驗頻率:45、50、55、60、65Hz單頻

45/55Hz、55/65Hz、47.5/52.5Hz自動雙變(bian)頻

頻率精度:±0.01Hz

外施高壓:正接線時大(da)試驗電流1A,工頻或變頻40-70Hz

反接線時大試驗電流10kV/1A,工頻或變頻40-70Hz

CVT自激法低壓(ya)輸出:輸出電壓(ya)3~50V,輸出電流3~30A

CVT變比測量:

變比(bi)測量精度:&plusmn;讀數×1%    變比(bi)測量范圍:10~99999

相位(wei)測量精度:±0.1°       相位(wei)測量范圍:0~359.9°

測(ce)量時間:約40s,與測(ce)量方式有關(guan)

輸(shu)入電(dian)(dian)(dian)源:180V~270VAC,50Hz±1%,市電(dian)(dian)(dian)或發(fa)電(dian)(dian)(dian)機(ji)供電(dian)(dian)(dian)

計算(suan)機接(jie)口:標(biao)準RS232接(jie)口

打印(yin)機:煒煌A7熱敏微型打印(yin)機

環境溫度:-10℃~50℃

相對濕度:<90%

外形尺寸:460×360×350mm

儀(yi)器重量:28kg

六、測量方式及原理

按(an)被測(ce)試品是否接(jie)地分(fen)兩種(zhong)測(ce)量(liang)(liang)方(fang)式(shi),即正接(jie)線(xian)(xian)測(ce)量(liang)(liang)方(fang)式(shi)和反接(jie)線(xian)(xian)測(ce)量(liang)(liang)方(fang)式(shi)。兩種(zhong)測(ce)量(liang)(liang)方(fang)式(shi)的原(yuan)理如(ru)圖一所示(shi):

在(zai)高壓電源的(de)10kV側,高壓分(fen)(fen)兩路(lu),一(yi)路(lu)給機內(nei)標(biao)準電容(rong)(rong)CN,此(ci)(ci)電容(rong)(rong)介損(sun)非常小,可以認為(wei)(wei)介損(sun)為(wei)(wei)零,即為(wei)(wei)純容(rong)(rong)性電流(liu),此(ci)(ci)電流(liu)ICN 可做為(wei)(wei)容(rong)(rong)性電流(liu)基準。在(zai)Cx試品一(yi)側,試品電流(liu)Icx通(tong)過采樣電阻R采入機內(nei),此(ci)(ci)Icx可分(fen)(fen)解成水平分(fen)(fen)量(liang)和垂(chui)(chui)直(zhi)分(fen)(fen)量(liang)見圖二所示(shi),通(tong)過計算水平分(fen)(fen)量(liang)與垂(chui)(chui)直(zhi)分(fen)(fen)量(liang)的(de)比值(zhi)即可得到tgδ值(zhi)。

在圖一(a)中Cx為非接地試(shi)品(pin),試(shi)品(pin)電(dian)流Icx從(cong)試(shi)品(pin)末端進(jin)入(ru)采樣(yang)電(dian)阻R,得(de)到全電(dian)流值,在圖一(b)中Cx為接地試(shi)品(pin),機(ji)內(nei)(nei)Cx端直(zhi)接接地,電(dian)流Icx從(cong)試(shi)品(pin)高壓端到機(ji)內(nei)(nei)采樣(yang)電(dian)阻取得(de)全電(dian)流值。

七、常見設備的接線方法

1.儀器引出端子說(shuo)明(ming):

HV ——  儀器的測量引線高壓端(帶(dai)危險電壓) 。

CX ——  正接線時試品電流輸入端。

——  儀器的接地端,使用時與大地可靠相接

2.參(can)考接線

2.1正接線(xian)、內標(biao)準電容、內高壓(常規正接線(xian)):

2.2反接(jie)線、內標準(zhun)電容(rong)、內高壓(常規(gui)反接(jie)線)

2.3正(zheng)接線、外(wai)標(biao)準電(dian)容、內高壓:

2.4反(fan)接線、外(wai)標準電容、內(nei)高壓:

2.5正接線、內標準電容、外高壓(ya):

2.6反(fan)接線、內(nei)標準電容、外高壓:

2.7正接(jie)線、外(wai)標準電容、外(wai)高壓(高電壓介損):

2.8反(fan)接線、外(wai)(wai)標(biao)準電(dian)容、外(wai)(wai)高(gao)壓:

2.9  CVT自激法測量:

CVT自激法可按(an)下圖接(jie)(jie)線(xian)。如果C1是單(dan)節電容(rong),母線(xian)不能接(jie)(jie)地(di);如果C1是多節電容(rong),母線(xian)可接(jie)(jie)地(di),C11和(he)C12可用(yong)常規正反接(jie)(jie)線(xian)測量,C13和(he)C2用(yong)自激法測量。

CVT自激法測(ce)量(liang)中,儀器先測(ce)量(liang)C1,然后自動(dong)倒(dao)線(xian)測(ce)量(liang)C2,并(bing)自動(dong)校準分壓影響。

應(ying)(ying)注(zhu)意(yi),高(gao)壓(ya)線應(ying)(ying)懸空不能接觸地面,否則其對地附加介損會(hui)引(yin)起(qi)誤差,可(ke)用細(xi)電(dian)纜連接高(gao)壓(ya)插座與CVT試品并吊起(qi)。強(qiang)烈(lie)建議使用高(gao)壓(ya)插座使用的(de)高(gao)壓(ya)線用黑色Cx線。

2.10 CVT變比測試

儀器高壓(ya)線(xian)(xian)的芯線(xian)(xian)紅(hong)夾子接CVT的上端(duan),母線(xian)(xian)拆地。CVT下端(duan)接地,低(di)壓(ya)線(xian)(xian)紅(hong)黑(hei)夾子接二(er)次繞(rao)組,注(zhu)意(yi):如果測試角度接近(jin)180度,應將紅(hong)黑(hei)夾子顛倒。

3.附(fu)加(jia)功能

3.1光標在 電壓:10kV上面時候,按“確認”鍵在儀器屏幕的左下角會出現圖標,代表測試結束自動打印。如果再按確認鍵,圖標消失,代表測試結束必須手動才能打印。

3.2光標在 反接 上面時候,在反接線,內Cn,內Un,情況下,按確認鍵在儀器屏幕右下角會出現圖標,代表反接線低壓屏蔽測試。如果再按確認鍵,圖標消失,代表取消反接線低壓屏蔽。

反接(jie)線低(di)壓屏蔽功能,一次接(jie)線可(ke)同時測出C1和C2的電容(rong)量和介(jie)損在反接(jie)線、內標(biao)準和內高壓方式(shi),光(guang)標(biao)移到(dao)“反接(jie)”處,按&ldquo;確認”右下(xia)角顯示(shi)“M”。

打開反(fan)接線(xian)(xian)低壓屏蔽,可在上端(duan)電(dian)容C1不拆母線(xian)(xian)的(de)情況下(xia),對其進行不拆線(xian)(xian)10kV反(fan)接線(xian)(xian)介損(sun)測(ce)量(liang)。如下(xia)圖所示:母線(xian)(xian)掛地線(xian)(xian),C1上端(duan)不拆線(xian)(xian),C1下(xia)端(duan)接高壓線(xian)(xian)芯線(xian)(xian),C2末端(duan)接Cx芯線(xian)(xian)。儀器采用反(fan)接線(xian)(xian)/10kV/M測(ce)量(liang)方式(shi),可同時測(ce)出C11和(he)下(xia)端(duan)屏蔽部分(fen)的(de)電(dian)容量(liang)和(he)介損(sun)值。

3.3光標在(zai) 正接 上面時候,按確認鍵(jian)則測試打印機,換紙。

3.4光標在 啟動 上(shang)面時候,按減(jian)小鍵則代表取出存儲的(de)數(shu)據。

3.5測試完畢,如果按減(jian)小鍵,則代表存儲測試的數據(ju)

八、儀(yi)器(qi)功(gong)能簡介

儀器面板見圖九(jiu)所示:

打(da)印(yin)機——打(da)印(yin)測量數據。

顯示器——128×64點陣液晶顯示器,顯示菜單和各種提示信息及測量結果。

鍵——選擇菜單項,被選中項反白字體顯示。

▲ &nbsp;鍵——修改菜單內容,采用循環滾動方(fang)式。

▼ 鍵——修改菜單內容,采用循環滾動方式。

確(que)認鍵(jian)——在“測試”選項上(shang)按此(ci)鍵(jian)進(jin)入測試狀態。

電源(yuan)開關(guan)—&mdash;整機電源(yuan)的開啟和關(guan)閉。

電(dian)源座——交流220V±10%,50±1Hz電(dian)源輸入口,帶保(bao)險倉。

9.自激法電流輸出端——測量CVT的(de)端子。

10.地——為接地線(xian)(xian)接線(xian)(xian)端子。

11.CX插座(zuo)——是試品信號的測(ce)量輸入端(duan),正接(jie)(jie)線(xian)時(shi)由(you)低(di)壓電纜連接(jie)(jie),此電纜單(dan)層屏蔽帶特(te)制鱷(e)魚夾(jia),長(chang)8m,接(jie)(jie)試品低(di)端(duan)。反接(jie)(jie)線(xian)時(shi)此端(duan)空置(zhi)。

12.CN插座——是外標(biao)準電容信號(hao)的測量輸(shu)入端,使用內標(biao)準時此端空置。

13.HV插座——高壓(ya)引出端子,由(you)高壓(ya)電纜連接,接試品(pin)高壓(ya)端。輸出10kv高壓(ya)。

14.RS-232接(jie)口,用來連接(jie)電腦(nao),上(shang)傳(chuan)數據(ju)。

 九、儀器操作(zuo)步驟(zou)

1.測量前準備:

 1)用接(jie)地(di)線一端(duan)接(jie)儀(yi)器(qi)的(de)接(jie)地(di)柱,另一端(duan)接(jie)可靠的(de)大地(di),保證儀(yi)器(qi)外殼處在地(di)電位上。

 2)正接線時:將(jiang)高壓電纜插(cha)(cha)頭插(cha)(cha)入后門HV插(cha)(cha)座中,將(jiang)另一端的(de)紅色(se)大(da)鉗子(zi)夾(jia)到被測試(shi)品(pin)的(de)引(yin)線上,黑色(se)小鉗子(zi)懸(xuan)空或夾(jia)在紅色(se)大(da)鉗子(zi)上。將(jiang)CX低壓電纜插(cha)(cha)入CX插(cha)(cha)座中,另一端的(de)紅色(se)夾(jia)子(zi)夾(jia)試(shi)品(pin)的(de)低端,黑色(se)夾(jia)子(zi)懸(xuan)空或接屏蔽裝置。

 3)反接線時:將(jiang)高(gao)壓(ya)電(dian)纜插頭插入后門(men)HV插座中(zhong),將(jiang)另一(yi)端(duan)的紅色大鉗(qian)子(zi)夾到被測(ce)試品的引線上(shang),紅色小鉗(qian)子(zi)懸空或(huo)接屏蔽裝置。Cx插座不(bu)用。

2.打開(kai)電源開(kai)關,儀器(qi)進行(xing)自(zi)(zi)檢,若自(zi)(zi)檢良好,液晶屏顯(xian)示中文(wen)主菜(cai)單如

圖十所示。

3.菜單選擇:

按   鍵可(ke)移動(dong)光標至各菜單項,并循環指(zhi)示(shi)。被選中(zhong)項反白字體顯示(shi)。選擇(ze)鍵的流程見(jian)圖十一所示(shi)。

在光標當(dang)前所示項(xiang)目(mu),按▼ ▲鍵(jian)(jian)鍵(jian)(jian)可(ke)進(jin)行該項(xiang)菜單的(de)變更,并循環指示,流程見圖十二所示。

將菜單變(bian)更至與測試要求(qiu)相對應后即可按選擇鍵(jian)進(jin)行下個(ge)項目的選擇。

4、&nbsp;頻(pin)(pin)(pin)率:光(guang)標在頻(pin)(pin)(pin)率上,按↑↓鍵(jian)選擇(ze)定頻(pin)(pin)(pin)和變頻(pin)(pin)(pin):

光標在定頻(pin)上:按(an)住“啟停(ting)”鍵(jian)1s以上切換到(dao)全頻(pin)率選擇,按(an)↑↓鍵(jian)循(xun)環(huan)顯示45Hz / 47.5Hz / 50Hz / 52.5Hz / 55Hz / 60Hz / 65Hz

工頻50Hz測量(liang),此設置不能抗干擾,在(zai)試驗室內測量(liang)或校驗時選用50Hz,“45/47.5/55/52.5/60/65Hz&rdquo;:為單頻率(lv)測量(liang),研究(jiu)不同頻率(lv)下介損(sun)的(de)變化時選用。

光標在(zai)變頻上:按(an)住(zhu)“啟停”鍵(jian)(jian)1s以上切(qie)換到(dao)全頻率選擇,按(an)↑↓鍵(jian)(jian)循環顯(xian)示5-Hz / 6-Hz / 4-Hz”:

“5-Hz&rdquo;:為45/55Hz自動(dong)變(bian)頻,適合50Hz電網工頻干擾下測量。

“6-Hz”:為(wei)55/65Hz自動變頻(pin),適合60Hz電網工頻(pin)干擾(rao)下測量。

“4-Hz”:為47.5/52.5Hz自動變頻(pin),適合50Hz電網工頻(pin)干擾下測量。

5、測(ce)(ce)(ce)(ce)(ce)試:當光標在 測(ce)(ce)(ce)(ce)(ce)試 項目(mu)上時(shi),按(an)確(que)(que)認鍵(jian)大約3秒鐘開(kai)始測(ce)(ce)(ce)(ce)(ce)試。測(ce)(ce)(ce)(ce)(ce)試過(guo)程(cheng)中(zhong)顯(xian)(xian)示(shi)的(de)畫面如(ru)圖十三(正接線(xian),變頻)所示(shi),當下面的(de)進(jin)程(cheng)到(dao)100%時(shi)候測(ce)(ce)(ce)(ce)(ce)試完畢(bi),然后顯(xian)(xian)示(shi)測(ce)(ce)(ce)(ce)(ce)量(liang)(liang)結果見圖十四所示(shi),此時(shi)光標指示(shi)打印機圖標,按(an)確(que)(que)認鍵(jian)打印報告。測(ce)(ce)(ce)(ce)(ce)量(liang)(liang)結果的(de)意義如(ru)下:

tgδ: 試品的損耗因(yin)數(shu)tgδ值

CX: 測量的電容值

V:施加電(dian)壓值(zhi)

I:試品流過(guo)的電流

F1,F2 : 試驗頻率(lv)

打印結束后,關閉電源(yuan)開關,測試完(wan)畢。

十、現場(chang)試驗(yan)注意事項

如(ru)果(guo)使(shi)用(yong)中(zhong)出現(xian)測試數據明顯(xian)不合理,請從以(yi)下方(fang)面查(cha)找原(yuan)因:

1、搭鉤接觸(chu)不(bu)良

現場測量(liang)使(shi)用搭(da)鉤連(lian)接(jie)(jie)試品時,搭(da)鉤務必與試品接(jie)(jie)觸(chu)良好,否則接(jie)(jie)觸(chu)點(dian)放電會引起數據嚴重(zhong)波動(dong)!尤其是引流線氧(yang)化層太厚,或風吹線擺(bai)動(dong),易(yi)造成接(jie)(jie)觸(chu)不良。

2、接地接觸(chu)不良

接(jie)地(di)不(bu)良會引起儀器保(bao)護或數據嚴重波動。應刮凈接(jie)地(di)點(dian)上(shang)的油漆和銹蝕,務必保(bao)證(zheng)0電阻接(jie)地(di)!

3、直接測量CVT或末端屏蔽法測量電磁(ci)式PT

直接測量(liang)CVT的下節耦合電(dian)容會出現負介損,應(ying)改(gai)用自激法(fa)。

用(yong)末端(duan)(duan)屏蔽法測量電磁式(shi)PT時(shi),由于受潮(chao)引起“T形網(wang)絡干擾”出現(xian)負介(jie)損,吹干下面三裙瓷套(tao)和接線端(duan)(duan)子盤(pan)即可。也可改(gai)用(yong)常規法或末端(duan)(duan)加壓法測量。

4、空氣濕(shi)度過大

空氣濕度大使(shi)介(jie)損測(ce)量值異常增大(或減小(xiao)甚至為負)且不穩定(ding),必要(yao)時可(ke)(ke)加屏蔽環。因人(ren)為加屏蔽環改變了(le)試(shi)品電場(chang)分布,此法有爭(zheng)議,可(ke)(ke)參照(zhao)有關規程。

5、發電機供電

發電(dian)機供(gong)電(dian)時輸入頻率不穩定(ding),可采用定(ding)頻50Hz模式工作(zuo)。

6、測試線

由于長期使用,易(yi)造(zao)成測(ce)試(shi)線隱性斷路,或芯線和屏蔽短路,或插頭接觸不良,用戶應經(jing)常維護測(ce)試(shi)線;

測試標準(zhun)電(dian)容試品時,應使用全屏蔽插頭連接,以消除附加雜(za)散電(dian)容影響,否(fou)則不能反映出儀(yi)器精度;

自激法測量CVT時,非的高壓線(xian)應(ying)吊起(qi)懸空(kong),否則對地附加雜(za)散電容和介損會引起(qi)測量誤差(cha)。

7、工作模式選擇

接好線(xian)后(hou)請選擇正(zheng)確(que)的測量工(gong)作(zuo)模式(正(zheng)、反和CVT),不可選錯。特別是干擾(rao)環(huan)境下應選用變(bian)頻抗干擾(rao)模式。

8、試驗方法影響

由于介損測量受試(shi)驗(yan)方法(fa)影響較大,應區分(fen)是試(shi)驗(yan)方法(fa)誤差還(huan)是儀(yi)器誤差。出現問題時(shi)可首先檢(jian)查(cha)接線,然后檢(jian)查(cha)是否為儀(yi)器故(gu)障(zhang)。

9、儀器故障

用萬用表測(ce)量一下測(ce)試線是否(fou)斷路(lu),或芯線和屏蔽是否(fou)短路(lu);輸入電(dian)源(yuan)220V過(guo)高(gao)或過(guo)低;接地是否(fou)良好。

用正、反接線測一下標準電容(rong)(rong)器或已(yi)知容(rong)(rong)量和介損的電容(rong)(rong)試品,如果(guo)結果(guo)正確,即可判(pan)斷儀(yi)器沒有問題;

拔下所(suo)有測試導線,進(jin)行空試升(sheng)壓,若不能(neng)正常工作,儀器可能(neng)有故障。

啟(qi)動(dong)CVT測(ce)量(liang)后測(ce)量(liang)低壓(ya)輸出,應出現2~5V電壓(ya),否則儀器有(you)故障。

十一、 儀器(qi)檢定

1、用標準損耗器檢定

用帶插頭的屏蔽電纜連(lian)接標(biao)(biao)準(zhun)損耗器。如果不能保(bao)證標(biao)(biao)準(zhun)損耗器的精度,應使(shi)用比對(dui)法檢定(ding)(ding),建議(yi)用2801電橋(qiao)(qiao)或(huo)其它(ta)精密電橋(qiao)(qiao)作(zuo)比對(dui)標(biao)(biao)準(zhun)。儀器應選用“內標(biao)(biao)準(zhun)”和“RC串聯試品”,可選擇工頻 50Hz或(huo)定(ding)(ding)頻50Hz頻率(lv)模式。

2、用QSJ3檢定:使用帶插頭(tou)的屏蔽電纜(lan)連接QSJ3,選擇“正接/ 外Cn / 外Un式(shi)測量,電流比為Cx∶Cn,Cn可置入適(shi)當值。

3、抗干擾能(neng)力(li)

設置一個回路向儀器注入(ru)定量的干(gan)擾電流(liu)。

注意:

1)應考慮到該回路可能成為(wei)試品的一部(bu)分。

2)儀(yi)器啟動(dong)后會使220V供電電路(lu)帶有測量頻率分(fen)量,如果該頻率分(fen)量又(you)通過干擾電流進入儀(yi)器,則無(wu)法檢驗儀(yi)器的抗干擾能力。

3)不建議用臨近高壓導體(ti)施加干擾,因為這(zhe)樣很容(rong)易(yi)產生近距離*放電,這(zhe)種放電電阻是非線性的,容(rong)易(yi)產生同頻干擾。

十(shi)二、變頻(pin)測量討(tao)論

1、變頻測量(liang)

干擾十分嚴(yan)重時(shi),變頻(pin)測量(liang)能得到準確可靠的結果。例如用55Hz測量(liang)時(shi),測量(liang)系統只允許55Hz信(xin)號通過,50Hz干擾信(xin)號被有效(xiao)抑制(zhi),原(yuan)因在于測量(liang)系統很容易(yi)區別不同頻(pin)率,由下述簡單計(ji)算可以(yi)說明選(xuan)頻(pin)測量(liang)的效(xiao)果:

兩個(ge)頻率相差1倍的正弦波疊加到一起,高(gao)頻的是干擾,幅度為低頻的10倍:

Y=1.234sin(x+5.678°)+12.34sin(2x+87.65°)

在x=0/90/180/270°得到4個(ge)測量值

Y0=12.4517,Y1= -11.1017,Y2=12.2075,Y3= -13.5576,

計算A=Y1-Y3=2.4559,B=Y0-Y2=0.2442,則(ze):

φ=tg-1(B/A)=5.678°     ; V=  A2+B2/2=1.234

這剛好(hao)是低(di)頻部分(fen)的(de)相(xiang)位和幅(fu)度,干擾(rao)被(bei)抑制。實際(ji)波(bo)形的(de)測量(liang)點多達數萬,計算量(liang)很(hen)大,結果反(fan)映(ying)了波(bo)形的(de)整體特征。

2、頻(pin)率和介損的關系

介損有RC串聯和并聯兩種(zhong)(zhong)理想模型(xing)(xing):串聯模型(xing)(xing)tgδ=2πfRC,并聯模型(xing)(xing)tgδ=1/(2πfRC),tgδ分別隨頻率f成(cheng)正(zheng)比和反比。如圖所示,f對*正(zheng)比和*反比兩種(zhong)(zhong)模型(xing)(xing)影(ying)響(xiang)(xiang)較(jiao)大。但實際電容器是多(duo)種(zhong)(zhong)模型(xing)(xing)交織的混合模型(xing)(xing),此時f的影(ying)響(xiang)(xiang)就(jiu)小。

3、自動(dong)變頻與(yu)50Hz等效

儀器采用自動變頻在干擾頻率50Hz兩側(45Hz和55Hz)各測一個點,然后推算50Hz頻率下數據。除多個元件電路的低頻諧振外,單個試品中的介質不可能在低頻引起能量吸收峰,工頻附近介損總是隨頻率單調變化的。因此這種測量方法不會帶來明顯誤差。實際上,平均前的兩個介損值已十分接近,即使不平均也*有參考價值。目前,變頻介損儀已成為介損測量的常規儀器,其優異的抗干擾能力和準確度已經得到認可。

十三、儀器的裝箱(xiang)清(qing)單(dan)

 

1.主機

一臺

2.高壓電纜

一條

3.低壓電纜

兩條

4.電源線

一條

5.地線

一條

6.CVT線

一條

7.5A保險管(內置)

兩只

8.打印紙

一卷

9.說明書

一本

10.出廠試驗報告

一份

11.合格證