中文字幕日韩欧美一区二区三区_亚洲人成色7777在线观看不卡_国产裸体舞一区二区三区_国产成人无码h在线观看网站

產品中心

當前位置:首頁-產品中心-油過濾及分析、試驗設備 - LYBS3000油酸值全自動測試儀 - 絕緣油酸值全自動分析儀

絕緣油酸值全自動分析儀

發布時間: 點擊量:588
絕緣油酸值全自動分析儀
 

一、LYBS3000絕緣油酸值全自動分析儀概(gai)述(shu)

是我公(gong)司科研技術(shu)人員,依據國家標準的相關(guan)規(gui)定,發(fa)揮自身(shen)優(you)勢,經過長期不懈努力,精(jing)心研制開發(fa)的高準確度、全數字化工業儀器(qi)。該(gai)機操作簡便(bian),造型美(mei)觀大方。儀器(qi)采(cai)用了全自動數字化微機控制,以化學分析之酸堿中和反應為基本框架,配以自行開發(fa)的背(bei)景(jing)空白扣除和滴定終點邏輯判定程(cheng)序(xu),所(suo)以測量(liang)的精(jing)密度和準確度均比較理想(xiang)。

變壓器(qi)和(he)汽輪機(ji)油酸值(zhi)的(de)(de)檢測是電力系統及工(gong)礦(kuang)企業充油電氣設備的(de)(de)常(chang)規檢驗項目(mu),而我公(gong)司針對上述油品(pin)酸值(zhi)測定而開發的(de)(de)設備。該(gai)儀器(qi)以單片微(wei)電腦為核心(xin),集光、機(ji)、電和(he)化(hua)學(xue)(xue)等多學(xue)(xue)科技術之大成。基本*替代了手工(gong)操作,即(ji)提高了工(gong)作效率,又減輕了操作人(ren)員的(de)(de)勞動(dong)強度(du),大限度(du)地減少了有機(ji)溶劑等化(hua)學(xue)(xue)藥(yao)品(pin)對人(ren)體(ti)的(de)(de)危害。

我公司采用(yong)中和法原理,于(yu)常溫狀態下,微機控制(zhi)自動完(wan)成(cheng)加液、攪拌、滴(di)定(ding)(ding)及終點判斷。采用(yong)觸摸式液晶屏選擇所有工(gong)作參數,人機對話(hua)界面簡潔友好(hao),操作方便,油樣平均分析周期為2分鐘(zhong)左右。可(ke)分別(bie)顯示多至35組(zu)的測定(ding)(ding)結果,并可(ke)打印輸(shu)出多項與測定(ding)(ding)相關(guan)的參數。

采用特(te)制(zhi)的(de)試(shi)劑瓶盛(sheng)裝(zhuang)(zhuang)萃取液(ye)(ye)和中(zhong)(zhong)(zhong)和液(ye)(ye)。其中(zhong)(zhong)(zhong)萃取液(ye)(ye)采用玻璃(li)(li)容器存儲,以保證無塑料(liao)添加劑污染物。中(zhong)(zhong)(zhong)和液(ye)(ye)選擇聚(ju)乙烯塑料(liao)瓶貯存,*避(bi)免了苛(ke)性(xing)(xing)鉀與玻璃(li)(li)反應的(de)可能(neng)。除(chu)此之外(wai),自行研發了中(zhong)(zhong)(zhong)和液(ye)(ye)平衡氣固體(ti)凈化(hua)(hua)(hua)裝(zhuang)(zhuang)置,*避(bi)免了二氧化(hua)(hua)(hua)碳和水蒸汽對(dui)中(zhong)(zhong)(zhong)和液(ye)(ye)濃度的(de)影響,更不會發生錯將(jiang)高濃度苛(ke)性(xing)(xing)鉀或苛(ke)性(xing)(xing)鈉凈化(hua)(hua)(hua)溶液(ye)(ye)當作(zuo)滴定標準溶液(ye)(ye)使用的(de)事故。工作(zuo)過程中(zhong)(zhong)(zhong)使用者無需用手接觸有機溶劑,減少了化(hua)(hua)(hua)學藥品(pin)對(dui)人體(ti)的(de)危害。

二、LYBS3000絕緣油酸值全自動分析儀?技術指(zhi)標

1. 線性范圍:  0.001~ 0.900 mgKOH/g; 

2. 相關系數:  0.999~0.9998

3. 回(hui) 收 率:  99 ~102%

4. 小分辨(bian)率:0.001 mgKOH/g

5. 重 復 性 : 2~5%(RSD)

6. 測(ce)量準(zhun)確度:

酸值在0.001~0.100 mgKOH/g之間為(wei) ± 0.003 mgKOH/g;

酸值(zhi)在0. 100~0.900 mgKOH/g之(zhi)間為示值(zhi)的2~5%;

7.顯示方式: 5.4″大屏(ping)幕觸(chu)摸式彩色液(ye)晶屏(ping)(全漢字(zi)顯示)

8. 外形尺寸:(寬)420 mm×(高(gao))190 mm×(縱深)340 mm

9. 凈    重(zhong): ;~ 9 kg

三、使用條件            

    1. 環境溫度 ;    0~40℃

   ; 2. 相對濕度    ≤ 85%

    3. 工作電源(yuan)     AC220V± 10%

    4. 電源(yuan)頻率     50Hz± 10%

5. 功率消(xiao)耗(hao)    <150 W

四(si)、機(ji)箱及面板部件(jian)圖示

<strong></strong>

<strong></strong>

五、操作(zuo)步驟(zou)圖解

1. 插接電源(yuan)線,打開(kai)電源(yuan)開(kai)關,液(ye)晶屏顯(xian)示開(kai)機頁(ye)面(圖4)

<strong></strong>

2. ;在圖4所示頁(ye)面下,按 初始(shi)化 鍵進(jin)入(ru)下一級頁(ye)面(圖5);

<strong></strong>

3. 在圖5所(suo)示(shi)頁面下,打開油樣測(ce)定(ding)(ding)暗室(shi)蓋(gai),用手輕輕撥動(dong)油杯(bei)(bei)(bei)盤,使廢(fei)(fei)液(ye)杯(bei)(bei)(bei)位(wei)孔偏離(li)滴定(ding)(ding)位(wei)置。取一只油杯(bei)(bei)(bei)放入廢(fei)(fei)液(ye)杯(bei)(bei)(bei)位(wei)孔內,按 系統(tong)清洗(xi)(xi) 鍵系統(tong)將(jiang)自動(dong)進(jin)行(xing)萃取和中和管(guan)路的清洗(xi)(xi),廢(fei)(fei)液(ye)杯(bei)(bei)(bei)將(jiang)承接清洗(xi)(xi)廢(fei)(fei)液(ye)。系統(tong)清洗(xi)(xi)頁面如圖6所(suo)示(shi)。

<strong></strong>

系統(tong)清洗(xi)完成(cheng)后按 返(fan)回 鍵(jian)回到(dao)(dao)初始化(hua)頁面(mian)(圖5)。在(zai)圖5所示頁面(mian)上(shang),按 萃取排氣(qi) 鍵(jian),同時(shi)打(da)開油樣測定暗室蓋,觀(guan)察排氣(qi)狀況(kuang),直(zhi)至無肉眼可見氣(qi)泡排出為止,按 返(fan)回 鍵(jian)回到(dao)(dao)初始化(hua)頁面(mian)(圖5)。同樣的步驟進行中和排氣(qi)操作;

<strong></strong>

初始(shi)化操作完成后,在(zai)圖5所示初始(shi)化頁(ye)面上按(an) 返回(hui)(hui)&nbsp;鍵回(hui)(hui)到開機頁(ye)面,按(an) 設置 鍵進入設置頁(ye)面(圖9)。

<strong></strong>

6. 在圖(tu)9頁面下,按 系統(tong)校準(zhun) 鍵進入系統(tong)校準(zhun)頁面(圖(tu)10)。

<strong></strong>

打開油樣(yang)測定暗(an)室蓋,于(yu)(yu)1、2號(hao)杯位的油杯中各加(jia)入1瓶儀器(qi)校(xiao)(xiao)準(zhun)(zhun)的標準(zhun)(zhun)酸(suan)(suan)溶液(ye),關閉測定暗(an)室蓋,按 校(xiao)(xiao)準(zhun)(zhun)啟動 鍵對系統進行校(xiao)(xiao)準(zhun)(zhun)。其(qi)中,1號(hao)杯中的標準(zhun)(zhun)酸(suan)(suan)溶液(ye)用(yong)于(yu)(yu)校(xiao)(xiao)準(zhun)(zhun)系統誤(wu)差(cha),2號(hao)杯中的標準(zhun)(zhun)酸(suan)(suan)溶液(ye)用(yong)于(yu)(yu)檢驗(yan)校(xiao)(xiao)準(zhun)(zhun)結(jie)果(guo)準(zhun)(zhun)確(que)度。校(xiao)(xiao)準(zhun)(zhun)過程中顯(xian)示圖11頁面(mian)。校(xiao)(xiao)準(zhun)(zhun)完成后,圖11所示頁面(mian)將顯(xian)示對系統的校(xiao)(xiao)準(zhun)(zhun)結(jie)果(guo)。系統校(xiao)(xiao)準(zhun)(zhun)的

<strong></strong>

理論值應(ying)(ying)為0.067 mgKOH/g,而實測值接近理論值即可。一(yi)般要求嚴格時(shi),應(ying)(ying)保證校準值在(zai)0.067±0.003 mgKOH/g范圍(wei)內。允許誤(wu)差較大時(shi),可按(an)實際(ji)情況(kuang)進行(xing)適當的(de)調整(zheng)。

7. 在設置頁面(mian),按(an) 杯位設定(ding) 鍵進入(ru)杯位設定(ding)頁面(mian)(圖12),按(an) 選擇 鍵選擇杯位號,按(an) Yes 或(huo) No 鍵命令該杯位參與測(ce)定(ding)或(huo)不參與測(ce)定(ding)。

<strong></strong>

在設置頁面(mian),按 時(shi)(shi)間設定(ding) 鍵進入時(shi)(shi)間設定(ding)頁面(mian)(圖(tu)13),按 選擇(ze) 鍵選擇(ze)年、月、日、時(shi)(shi)、分(fen),按+ 或 — 鍵改變設定(ding)值,然后(hou)按 返(fan)回(hui)(hui) 鍵回(hui)(hui)到設置頁面(mian)。

<strong></strong>

在(zai)(zai)正(zheng)(zheng)式的樣(yang)(yang)品(pin)測(ce)(ce)定(ding)(ding)前,應將(jiang)潔凈(jing)的樣(yang)(yang)品(pin)油(you)杯(bei)(bei)水平(ping)放置在(zai)(zai)相應的杯(bei)(bei)位孔內,在(zai)(zai)每個測(ce)(ce)定(ding)(ding)油(you)杯(bei)(bei)中(zhong)準(zhun)確平(ping)行注入(ru)待(dai)測(ce)(ce)樣(yang)(yang)品(pin)油(you)10.0mL(或在(zai)(zai)油(you)杯(bei)(bei)中(zhong)稱量待(dai)測(ce)(ce)樣(yang)(yang)品(pin)油(you)8.3~8.5g,并將(jiang)油(you)杯(bei)(bei)歸位),加(jia)入(ru)一只攪拌(ban)磁棒,蓋(gai)上(shang)樣(yang)(yang)品(pin)測(ce)(ce)定(ding)(ding)暗室(shi)蓋(gai)。在(zai)(zai)開機頁(ye)面(圖4)按(an) 開始(shi) 鍵進行測(ce)(ce)定(ding)(ding),同(tong)時顯示屏顯示測(ce)(ce)試(shi)(shi)(shi)頁(ye)面,屏幕在(zai)(zai)不同(tong)測(ce)(ce)試(shi)(shi)(shi)階段(duan)分(fen)別顯示“X號杯(bei)(bei)測(ce)(ce)試(shi)(shi)(shi)中(zhong),請(qing)稍后......”、“正(zheng)(zheng)在(zai)(zai)滴(di)定(ding)(ding)”,測(ce)(ce)定(ding)(ding)完成后還(huan)會顯示“滴(di)定(ding)(ding)終點(EP)值(zhi)”(圖14)及“測(ce)(ce)試(shi)(shi)(shi)完畢”(圖15)等(deng)字樣(yang)(yang)。

<strong></strong>

<strong></strong>

10. 測定(ding)完(wan)成后,本機(ji)(ji)自動保存(cun)35組數據(ju)。操作人員如果想查閱,請按(an)返(fan)回鍵進入開(kai)機(ji)(ji)頁(ye)面(mian)(圖4),點(dian)擊查閱鍵進入查閱頁(ye)面(mian)(圖16),點(dian)擊上一(yi)頁(ye)或下一(yi)頁(ye)鍵可查看編號(hao)01~35號(hao)組數據(ju),點(dian)擊打印鍵可以通(tong)過打印機(ji)(ji)輸出所需數據(ju)。

<strong></strong>

六.維護與(yu)保(bao)養

1.每(mei)次使(shi)用完畢(bi)后,萃取液(ye)(ye)和(he)(he)(he)中和(he)(he)(he)液(ye)(ye)輸液(ye)(ye)蠕動(dong)泵壓板必須松開,以防輸液(ye)(ye)泵管(guan)被長期擠壓變形和(he)(he)(he)粘(zhan)連(lian),影響(xiang)測定精密度(du)(du)和(he)(he)(he)準確度(du)(du)。若長時間停機,請(qing)(qing)將中和(he)(he)(he)液(ye)(ye)輸液(ye)(ye)蠕動(dong)泵管(guan)取下,放入(ru)隨(sui)機附帶的(de)“中和(he)(he)(he)液(ye)(ye)蠕動(dong)泵管(guan)活化(hua)液(ye)(ye)”中密封浸泡。再次使(shi)用時,請(qing)(qing)參考圖3復位安裝即可;

2.每次使用(yong)完(wan)畢,必須用(yong)無(wu)水乙醇沖洗(xi)中和液、萃取液輸液管路(lu),防止沉淀物堵塞管路(lu)和微型滴定針頭;

3.輸液泵(beng)管中段經(jing)長(chang)時間使用后材料會自然(ran)老化,若發現嚴(yan)重的硬化、變形(xing)或粘連(lian),應給予維護或更換。更換時,將泵(beng)管從蠕動泵(beng)凹槽(cao)中取出,換上新泵(beng)管,原樣復(fu)位并與相關部(bu)件(jian)正確(que)連(lian)接即可;

4.更換(huan)(huan)萃取液(ye)和中和液(ye)時(shi),應將用盡(jin)的溶液(ye)瓶取下,然后換(huan)(huan)上新溶液(ye)瓶即可,更換(huan)(huan)過(guo)程中應注意管路的污染問題(ti);

5. 當CO2、H2O凈(jing)(jing)化器(qi)中凈(jing)(jing)化劑的(de)顏色(se)明顯(xian)由(you)粉紅色(se)變為灰白色(se)時,應當更換凈(jing)(jing)化器(qi),否則會影響(xiang)中和液穩定性,直至影響(xiang)測定結果的(de)準確度;

6. 更換打印色帶:

色(se)帶盒在打印(yin)機(ji)出廠時以經裝好,但經過(guo)一段時期(qi)使用(yong)后(hou),需要(yao)更換色(se)帶盒。可以按下(xia)面(mian)步驟更換色(se)帶盒。

(1)拉(la)出色帶倉。

(2)從打印(yin)機頭上輕(qing)輕(qing)取下舊(jiu)色(se)帶(dai)(dai)盒(he)(he)。注意:請先抬(tai)起色(se)帶(dai)(dai)盒(he)(he)的左(zuo)端,然(ran)后在抬(tai)起色(se)帶(dai)(dai)盒(he)(he)的右(you)端,取下色(se)帶(dai)(dai)盒(he)(he)。

(3)換新的(de)(de)(de)色(se)(se)(se)(se)帶(dai)(dai)(dai)(dai)盒(he)(he)(he)(he)。首先(xian)將色(se)(se)(se)(se)帶(dai)(dai)(dai)(dai)盒(he)(he)(he)(he)的(de)(de)(de)右(you)(you)端(duan)輕輕放在機頭(tou)右(you)(you)端(duan)的(de)(de)(de)齒輪軸(zhou)上,左端(duan)稍(shao)微(wei)抬(tai)起,不要放下(xia)。這時(shi)如發現(xian)色(se)(se)(se)(se)帶(dai)(dai)(dai)(dai)盒(he)(he)(he)(he)右(you)(you)端(duan)為(wei)落到(dao)底(di),請(qing)用手指按住色(se)(se)(se)(se)帶(dai)(dai)(dai)(dai)盒(he)(he)(he)(he)上的(de)(de)(de)旋(xuan)鈕,順時(shi)針方向稍(shao)微(wei)轉動(dong)一下(xia),直(zhi)到(dao)色(se)(se)(se)(se)帶(dai)(dai)(dai)(dai)盒(he)(he)(he)(he)的(de)(de)(de)右(you)(you)端(duan)落到(dao)底(di)后再(zai)放下(xia)色(se)(se)(se)(se)帶(dai)(dai)(dai)(dai)盒(he)(he)(he)(he)的(de)(de)(de)左端(duan)。請(qing)檢查色(se)(se)(se)(se)帶(dai)(dai)(dai)(dai)是(shi)否拉(la)直(zhi),或色(se)(se)(se)(se)帶(dai)(dai)(dai)(dai)還(huan)露在色(se)(se)(se)(se)帶(dai)(dai)(dai)(dai)盒(he)(he)(he)(he)的(de)(de)(de)外面(mian),可再(zai)旋(xuan)動(dong)色(se)(se)(se)(se)帶(dai)(dai)(dai)(dai)盒(he)(he)(he)(he)上的(de)(de)(de)旋(xuan)鈕,直(zhi)到(dao)把色(se)(se)(se)(se)帶(dai)(dai)(dai)(dai)拉(la)入色(se)(se)(se)(se)帶(dai)(dai)(dai)(dai)盒(he)(he)(he)(he)內(nei)并拉(la)直(zhi)為(wei)止(zhi)。當沒有紙在機頭(tou)里時(shi),更換色(se)(se)(se)(se)帶(dai)(dai)(dai)(dai)更加容易。

(4)把色(se)帶倉(cang)推入復位,更(geng)換完畢(bi)。

7. 更換打印紙:

(1)拉出(chu)紙(zhi)(zhi)(zhi)倉(cang),取下紙(zhi)(zhi)(zhi)卷(juan)軸(zhou)更換打(da)印(yin)紙(zhi)(zhi)(zhi),并將(jiang)紙(zhi)(zhi)(zhi)卷(juan)軸(zhou)用力按入(ru)打(da)印(yin)機的導(dao)槽內。一定要確(que)認(ren)紙(zhi)(zhi)(zhi)卷(juan)軸(zhou)已安裝牢(lao)固,不會掉(diao)出(chu)。

(2)將紙(zhi)端剪成三角形,接通儀(yi)器電源,按SEL(左)鍵(jian)(jian),使SEL指示(shi)燈滅,然后再(zai)按LF(右)鍵(jian)(jian),使機頭(tou)轉動。這(zhe)時(shi)用手將紙(zhi)頭(tou)送入機頭(tou)下(xia)面紙(zhi)口處,紙(zhi)便會徐徐進入機頭(tou),直(zhi)到從機頭(tou)正前方露出(chu)為止,露出(chu)應有(you)一定長度。再(zai)按一下(xia)LF或(huo)SEL鍵(jian)(jian),或(huo)關上電源。

(3)把(ba)紙倉推(tui)入(ru)復位即可。

七.隨機(ji)附(fu)件(jian)

1.電源線(xian)           &nbsp;         1條(tiao)

2.保險管(3A)             &nbsp; 2只

3.油杯(bei)        &nbsp;       &nbsp;      4只

4.攪拌磁(ci)棒            &nbsp;      4只

5.中(zhong)和(he)滴定針(zhen)頭        &nbsp;      6只

6.  萃取加液針(zhen)頭          &nbsp;    2只

7.萃取液泵管        &nbsp;        2條

8.中和液泵管(guan)                 1條(tiao)

9.萃取液(ye)防(fang)塵瓶(ping)蓋  &nbsp;          1套

10.CO2、H2O凈(jing)化(hua)器膠(jiao)塞   1套

11. 中和液瓶膠塞           1套

12.萃取(qu)溶液(ye)  ;                2瓶(500 mL×2) 

13.中(zhong)和(he)溶液           &nbsp;  ;    1瓶(250 mL×1)

14. 標準酸溶液(儀器校準用) &nbsp; 4瓶(8 mL×4)

15.操作手(shou)冊(ce)                  1本

16.打印紙        &nbsp;           1卷

17.裝箱單            ;        1份

八.售后服(fu)務

1.本產品保(bao)修(xiu)18個月,終身服務(wu)。

2.本公司長(chang)年供應相關試(shi)劑(ji)和耗材(cai)。

一、產品概述

是(shi)在同類產品(pin)YDJ(G)型高(gao)壓試(shi)驗變(bian)壓器(qi)的基礎(chu)上,按試(shi)驗變(bian)壓器(qi)國家標準ZBK41006—89要求,經改進后生產的一種(zhong)新型產品(pin),本系列產品(pin)具有體積小(xiao)、重量輕、結(jie)構緊湊、功能齊全、使用方便等特點。實用于電力、工(gong)礦、科研等部門,對各種(zhong)高(gao)壓電氣設備、電氣元件、絕緣材料進行工(gong)頻(pin)耐壓試(shi)驗和直流泄漏試(shi)驗,是(shi)高(gao)壓試(shi)驗中(zhong)*的儀器(qi)。

二、產品結構

鐵芯(xin)為單框式。線圈采用(yong)同芯(xin)圓(yuan)筒(tong)多層塔式結構(gou),初級低(di)壓繞(rao)(rao)組繞(rao)(rao)在鐵芯(xin)上(shang),次級高壓繞(rao)(rao)組繞(rao)(rao)在低(di)壓繞(rao)(rao)組外側,這種同軸布置減少了(le)繞(rao)(rao)組間的藕合損耗。高壓硅堆用(yong)特殊工藝封裝在套管內(nei),產品(pin)的外殼制成與器(qi)芯(xin)配合較佳的八角形結構(gou),整體外型美觀大(da)方。其內(nei)外部結構(gou)見圖1。

產(chan)品型號含義(yi)

                        圖1:YDQC系列高壓變壓器結構示意(yi)圖

1-均(jun)壓(ya)(ya)(ya)(ya)(ya)球;2-硅(gui)堆短路(lu)桿;3-高(gao)(gao)壓(ya)(ya)(ya)(ya)(ya)套管;4-油閥;5-殼體(ti);6、7-調整(zheng)電壓(ya)(ya)(ya)(ya)(ya)輸入(ru)a、x端(duan)子(zi);8、9-儀(yi)表測(ce)量E、F端(duan)子(zi);10-高(gao)(gao)壓(ya)(ya)(ya)(ya)(ya)尾X端(duan)子(zi);11-變壓(ya)(ya)(ya)(ya)(ya)器(qi)外(wai)殼接地端(duan);12-高(gao)(gao)壓(ya)(ya)(ya)(ya)(ya)輸出A端(duan)子(zi);13-高(gao)(gao)壓(ya)(ya)(ya)(ya)(ya)整(zheng)流硅(gui)堆;14-內部均(jun)壓(ya)(ya)(ya)(ya)(ya)環(huan);15-變壓(ya)(ya)(ya)(ya)(ya)器(qi)鐵芯;16-初級低壓(ya)(ya)(ya)(ya)(ya)繞組;17-測(ce)量儀(yi)表繞組;18-二(er)次(ci)級高(gao)(gao)壓(ya)(ya)(ya)(ya)(ya)繞組;19-變壓(ya)(ya)(ya)(ya)(ya)器(qi)油。

三(san)、工作(zuo)原(yuan)理

為(wei)(wei)單相變壓(ya)器,聯(lian)結(jie)組(zu)標號II。單臺高壓(ya)試驗(yan)變壓(ya)器的(de)工(gong)作過程,用交流220V(10KVA以(yi)上(shang)為(wei)(wei)380V)電(dian)壓(ya)接(jie)入電(dian)源(yuan)(yuan)控制箱(臺),經電(dian)源(yuan)(yuan)控制箱(臺)內自(zi)藕調(diao)壓(ya)器(50KVA以(yi)上(shang)調(diao)壓(ya)器外(wai)附)調(diao)節(jie)0~200V(10KVA以(yi)上(shang)0~400V)電(dian)壓(ya)至試驗(yan)變壓(ya)器的(de)初(chu)級繞(rao)組(zu),根據電(dian)磁感(gan)應原理,在試驗(yan)變壓(ya)器高壓(ya)繞(rao)組(zu)可獲得試驗(yan)所(suo)需的(de)高電(dian)壓(ya)。其工(gong)作原理圖(tu)見圖(tu)2所(suo)示。

1、單(dan)臺(tai)YDQC高壓試(shi)驗(yan)變(bian)壓器工作(zuo)原(yuan)理示意圖

                    圖2 :單臺YDQC高壓試驗變壓器工作原理示意圖
在試驗變壓器中:a、x為低壓輸入端;A、X 為高壓輸出端;E、F為儀表測量端。

2、單臺交直流(liu)兩用型(xing)高(gao)(gao)(gao)(gao)壓(ya)試驗(yan)變壓(ya)器工作原理見圖(tu)(tu)3。圖(tu)(tu)中所示:高(gao)(gao)(gao)(gao)壓(ya)套管內裝有高(gao)(gao)(gao)(gao)壓(ya)硅堆,串接在高(gao)(gao)(gao)(gao)壓(ya)回路(lu)(lu)中作高(gao)(gao)(gao)(gao)壓(ya)整流(liu),以獲得(de)直流(liu)高(gao)(gao)(gao)(gao)電(dian)壓(ya)。當用一短(duan)路(lu)(lu)桿將高(gao)(gao)(gao)(gao)壓(ya)硅堆短(duan)接時,可(ke)獲得(de)交流(liu)高(gao)(gao)(gao)(gao)電(dian)壓(ya),其狀(zhuang)態(tai)為交流(liu)輸(shu)出(chu)(chu);反(fan)之在抽(chou)出(chu)(chu)短(duan)路(lu)(lu)桿時,其狀(zhuang)態(tai)為直流(liu)輸(shu)出(chu)(chu)。
3、三臺(tai)高(gao)壓(ya)(ya)試(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)器(qi)(qi)(qi)(qi)串(chuan)(chuan)激(ji)獲得更(geng)高(gao)電(dian)壓(ya)(ya)原理見圖4,串(chuan)(chuan)激(ji)高(gao)壓(ya)(ya)試(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)器(qi)(qi)(qi)(qi)有很大的優越性,因為(wei)(wei)整個試(shi)(shi)驗(yan)(yan)(yan)(yan)裝(zhuang)置(zhi)由多個單(dan)(dan)臺(tai)串(chuan)(chuan)激(ji)式試(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)器(qi)(qi)(qi)(qi)組(zu)成,單(dan)(dan)臺(tai)試(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)器(qi)(qi)(qi)(qi)有著體積小、重量輕、便于運輸(shu)(shu)的特(te)點,它既可以串(chuan)(chuan)接成高(gao)出幾倍(bei)的單(dan)(dan)臺(tai)試(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)器(qi)(qi)(qi)(qi)輸(shu)(shu)出電(dian)壓(ya)(ya)組(zu)合使用(yong),又可以分開單(dan)(dan)獨(du)使用(yong)。整套試(shi)(shi)驗(yan)(yan)(yan)(yan)裝(zhuang)置(zhi)投資(zi)小、經濟實(shi)惠。圖3所示:在(zai)(zai)三臺(tai)串(chuan)(chuan)激(ji)式試(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)器(qi)(qi)(qi)(qi)串(chuan)(chuan)激(ji)使用(yong)中,單(dan)(dan)臺(tai)試(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)器(qi)(qi)(qi)(qi)B1、B2、B3的輸(shu)(shu)出電(dian)壓(ya)(ya)都(dou)是U,*、二級(ji)(ji)(ji)的試(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)器(qi)(qi)(qi)(qi)內部(bu)都(dou)有一(yi)個激(ji)磁(ci)(ci)繞組(zu),分別(bie)為(wei)(wei)A1、C1 和(he)A2、C2。當控制電(dian)壓(ya)(ya)加在(zai)(zai)*級(ji)(ji)(ji)試(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)器(qi)(qi)(qi)(qi)B1的初(chu)級(ji)(ji)(ji)繞組(zu)a1、x1上,激(ji)磁(ci)(ci)繞組(zu)A1、C1給予(yu)試(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)器(qi)(qi)(qi)(qi)B2初(chu)級(ji)(ji)(ji)繞組(zu)供(gong)電(dian),第二級(ji)(ji)(ji)試(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)器(qi)(qi)(qi)(qi)B2的激(ji)磁(ci)(ci)繞組(zu)A2、C2給試(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)器(qi)(qi)(qi)(qi)B3的初(chu)級(ji)(ji)(ji)繞組(zu)供(gong)電(dian)。由于*級(ji)(ji)(ji)試(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)器(qi)(qi)(qi)(qi)B1的高(gao)壓(ya)(ya)尾及殼體接地,第二、三級(ji)(ji)(ji)的試(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)器(qi)(qi)(qi)(qi)B2和(he)B3對(dui)地有絕緣支架的隔離,這樣(yang)試(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)器(qi)(qi)(qi)(qi)B1、B2、B3對(dui)地輸(shu)(shu)出電(dian)壓(ya)(ya)分別(bie)為(wei)(wei)1U、2U、3U。

                     圖3:三臺高壓試驗變壓器串激工作原理示意圖
B1、B2、B3- 串激式高壓變壓器;1U、2U、3U-各級對地電壓;
PV- 高壓示值表(KV); ZJ1、ZJ2-絕緣支架。

四、使用方(fang)法及(ji)注(zhu)意事項    

1、做(zuo)工(gong)(gong)頻耐壓(ya)(ya)(ya)(ya)試(shi)驗使用接線方法(fa)見圖5。做(zuo)工(gong)(gong)頻耐壓(ya)(ya)(ya)(ya)試(shi)驗前,先根據(ju)試(shi)驗變(bian)壓(ya)(ya)(ya)(ya)器(qi)的(de)額定容量(liang)選擇(ze)好限流電(dian)阻(zu),(水電(dian)阻(zu))的(de)阻(zu)值,再根據(ju)被試(shi)品需加的(de)高(gao)壓(ya)(ya)(ya)(ya)電(dian)壓(ya)(ya)(ya)(ya)值調整(zheng)好放電(dian)球隙的(de)球間距,為了(le)提高(gao)對被試(shi)品施加電(dian)壓(ya)(ya)(ya)(ya)的(de)測量(liang)精度,應在高(gao)壓(ya)(ya)(ya)(ya)側(ce)接入FRC阻(zu)容分(fen)壓(ya)(ya)(ya)(ya)器(qi)來測量(liang)電(dian)壓(ya)(ya)(ya)(ya)。

                     圖4:工頻耐壓試驗使用接線原理示意圖
R1、R2- 限流電阻; Qx- 放電球隙; Zx- 被試品;
FRC- 阻容分壓器; V- 分壓器高壓表。
 
按照圖4、結合(he)圖2所進行的(de)工頻(pin)耐(nai)壓(ya)(ya)試(shi)驗接(jie)好工作線路,試(shi)驗變(bian)壓(ya)(ya)器的(de)高(gao)(gao)壓(ya)(ya)繞阻的(de)X端(高(gao)(gao)壓(ya)(ya)尾)、儀表測(ce)量(liang)繞組的(de)F端、試(shi)驗變(bian)壓(ya)(ya)器的(de)外殼(ke)以及電(dian)源控制箱(臺)的(de)外殼(ke)必須(xu)可靠接(jie)地。
用三臺(tai)試驗變壓(ya)(ya)器(qi)(qi)(qi)串激做工頻耐壓(ya)(ya)試驗時、第(di)(di)二(er)、三級(ji)試驗變壓(ya)(ya)器(qi)(qi)(qi)的初級(ji)繞(rao)組(zu)X端,儀表(biao)測量繞(rao)組(zu)的F端,以及高壓(ya)(ya)繞(rao)組(zu)的X端(高壓(ya)(ya)尾(wei))均接本級(ji)試驗變壓(ya)(ya)器(qi)(qi)(qi)的外殼,第(di)(di)二(er)、三級(ji)試驗變壓(ya)(ya)器(qi)(qi)(qi)的主體必須放置在絕緣支架上。除(chu)*級(ji)以外、第(di)(di)二(er)、三級(ji)試驗變壓(ya)(ya)器(qi)(qi)(qi)的主體不(bu)要接地線(xian)。其接線(xian)方式見(jian)圖3所示(shi)。
接(jie)電(dian)源前,電(dian)源控制箱(臺)的調(diao)(diao)壓器必須調(diao)(diao)到零(ling)位。接(jie)通電(dian)源后,綠色指(zhi)示燈亮,按(an)一下啟動按(an)鈕,紅色指(zhi)示燈亮,表示試驗(yan)變壓器已(yi)接(jie)通控制電(dian)源,開始升壓。
從零位開(kai)始按(an)順時(shi)針方向勻速(su)(su)(su)旋轉調壓(ya)(ya)(ya)(ya)(ya)(ya)器手(shou)輪升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)。(升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)方式有(you):快速(su)(su)(su)升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)法(fa),即(ji)20S逐級升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)法(fa),慢速(su)(su)(su)升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)法(fa),即(ji)60S逐級升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)法(fa),極慢速(su)(su)(su)升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)法(fa)供選(xuan)用)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)從零開(kai)始按(an)選(xuan)定(ding)(ding)的升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)速(su)(su)(su)度升(sheng)(sheng)(sheng)到您所(suo)需額(e)定(ding)(ding)試(shi)(shi)(shi)驗(yan)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)的75%后,再以每秒(miao)2%額(e)定(ding)(ding)試(shi)(shi)(shi)驗(yan)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)的速(su)(su)(su)度升(sheng)(sheng)(sheng)到您所(suo)需試(shi)(shi)(shi)驗(yan)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya),并密切注意測量儀(yi)表(biao)的指示以及(ji)被試(shi)(shi)(shi)品的情(qing)況,被試(shi)(shi)(shi)品施加電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)的時(shi)間到后。應在數秒(miao)內勻速(su)(su)(su)將調壓(ya)(ya)(ya)(ya)(ya)(ya)器返回,高(gao)壓(ya)(ya)(ya)(ya)(ya)(ya)降至1/3試(shi)(shi)(shi)驗(yan)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)以下,按(an)一(yi)下停止(zhi)按(an)鈕,高(gao)壓(ya)(ya)(ya)(ya)(ya)(ya)、低壓(ya)(ya)(ya)(ya)(ya)(ya)輸出停止(zhi),然后切斷電(dian)(dian)源(yuan)線,試(shi)(shi)(shi)驗(yan)完畢。

工頻耐(nai)壓(ya)試驗操(cao)作過程注意事項

1、試驗人(ren)員應(ying)做好責任(ren)分工(gong),設定(ding)好試驗現場的(de)安全距離(li),仔細檢(jian)查好被(bei)試品及(ji)試驗變壓器的(de)接地情況(kuang),并設有專人(ren)監護安全及(ji)觀察(cha)被(bei)試品狀態(tai)工(gong)作。
2、被(bei)試品主要部(bu)位(wei)應(ying)清除干(gan)凈,保持干(gan)燥,以免(mian)損壞(huai)被(bei)試品和(he)帶來試驗數值(zhi)的誤(wu)差。
3、對(dui)(dui)大型設備的(de)(de)試驗,一般都應先進行試驗變壓(ya)器的(de)(de)空升試驗,即(ji)不接試品時升壓(ya)至試驗電壓(ya),以便校對(dui)(dui)好儀表的(de)(de)指示精度,調整(zheng)好放電球隙的(de)(de)球間距。
4、做(zuo)耐壓(ya)(ya)(ya)試(shi)驗(yan)時(shi)升壓(ya)(ya)(ya)速度不(bu)能過(guo)快,并防止突然加壓(ya)(ya)(ya),例如調壓(ya)(ya)(ya)器不(bu)在(zai)零位(wei)的突然合閘,也不(bu)能突然斷電,一般應在(zai)調壓(ya)(ya)(ya)器降至零位(wei)時(shi)分閘。
5、在升(sheng)壓(ya)(ya)(ya)或耐壓(ya)(ya)(ya)試(shi)(shi)驗過程(cheng)中,如發現下列不(bu)正常情況,1 電(dian)壓(ya)(ya)(ya)、電(dian)流(liu)表指針擺動(dong)很大,2 被試(shi)(shi)品發出不(bu)正常響聲,3 發現絕緣有燒焦(jiao)或冒煙(yan)現象,應立即降(jiang)壓(ya)(ya)(ya),切斷電(dian)源,停(ting)止試(shi)(shi)驗并查明原因。
6、使用本(ben)產品做高壓(ya)試驗時,除熟(shu)悉本(ben)說明書外,還(huan)必(bi)須嚴(yan)格執行國家有關標(biao)準和操(cao)作規程。

2、做(zuo)直流耐壓(ya)(ya)和泄(xie)漏試(shi)驗(yan)使(shi)用接(jie)線方(fang)法見圖5。由于是交直流兩用高(gao)(gao)壓(ya)(ya)試(shi)驗(yan)變(bian)壓(ya)(ya)器(qi),應把(ba)高(gao)(gao)壓(ya)(ya)硅堆(dui)短路桿(gan)從套管中(zhong)抽出(chu)(chu),使(shi)試(shi)驗(yan)變(bian)壓(ya)(ya)器(qi)為直流輸出(chu)(chu)狀(zhuang)態。做(zuo)直流泄(xie)漏試(shi)驗(yan)前,先根據(ju)(ju)泄(xie)漏試(shi)驗(yan)中(zhong)輸出(chu)(chu)端斷路電(dian)(dian)(dian)流不(bu)超過高(gao)(gao)壓(ya)(ya)硅堆(dui)的(de)大整流為宜,選擇好(hao)(hao)限流電(dian)(dian)(dian)阻(zu)(水電(dian)(dian)(dian)阻(zu))的(de)阻(zu)值(zhi),再根據(ju)(ju)被(bei)(bei)試(shi)品(pin)對(dui)直流高(gao)(gao)壓(ya)(ya)波形(xing)的(de)要求選擇好(hao)(hao)高(gao)(gao)壓(ya)(ya)濾(lv)波電(dian)(dian)(dian)容的(de)電(dian)(dian)(dian)容值(zhi)。為了提(ti)高(gao)(gao)對(dui)被(bei)(bei)試(shi)品(pin)施加電(dian)(dian)(dian)壓(ya)(ya)的(de)測量(liang)(liang)精度,應在高(gao)(gao)壓(ya)(ya)側接(jie)入(ru)FRC阻(zu)容分壓(ya)(ya)器(qi)來測量(liang)(liang)電(dian)(dian)(dian)壓(ya)(ya)。 

                       圖 5:直流泄漏試驗使用接線原理示意圖
R- 限流電阻; C- 高壓濾波電容; Zx- 被試品; G- 硅堆短路桿;
FRC- 阻容分壓器;V- 分壓器高壓表;uA- 微安表;D- 高壓整流硅堆。

按照圖5、結合圖3所進行(xing)的(de)(de)直流泄漏試(shi)驗(yan)接好工作線路。試(shi)驗(yan)變壓器(qi)的(de)(de)高壓繞組(zu)的(de)(de)X端(高壓尾)、儀表測量繞組(zu)的(de)(de)F 端、試(shi)驗(yan)變壓器(qi)的(de)(de)外殼(ke)以及電源控制箱(臺)的(de)(de)外殼(ke)必(bi)須可靠(kao)接地。

YDQC試驗變做交流試驗接線原理圖

YDQC試驗變做交流泄漏試驗接線原理圖
     接電(dian)源(yuan)前、電(dian)源(yuan)控(kong)制箱(臺(tai))的調(diao)壓器必須調(diao)到零位。接通電(dian)源(yuan)后,綠色(se)指示燈亮,按

一下啟動按鈕,紅色指示燈亮,表示試(shi)驗變壓器已接通控(kong)制電源,開始(shi)升壓。
從(cong)零位開始按(an)順時針方向勻速(su)(su)旋轉調壓(ya)(ya)(ya)(ya)(ya)器(qi)手輪升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)。(升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)方式有:快速(su)(su)升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)法(fa)(fa)即20S逐級升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)法(fa)(fa);慢速(su)(su)升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)法(fa)(fa),即60S逐級升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)法(fa)(fa);級慢速(su)(su)升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)法(fa)(fa)供選用)電壓(ya)(ya)(ya)(ya)(ya)從(cong)零開始按(an)選定的(de)升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)速(su)(su)度升(sheng)(sheng)(sheng)到您所需(xu)額定試(shi)驗(yan)電壓(ya)(ya)(ya)(ya)(ya)或額定直(zhi)流(liu)電流(liu)下的(de)參考電壓(ya)(ya)(ya)(ya)(ya)。試(shi)驗(yan)中應嚴(yan)密注意直(zhi)流(liu)高(gao)壓(ya)(ya)(ya)(ya)(ya)表(biao)、泄漏電流(liu)表(biao)指(zhi)示以及(ji)被(bei)試(shi)品的(de)情(qing)況。試(shi)驗(yan)完畢后,應訊速(su)(su)均勻將高(gao)壓(ya)(ya)(ya)(ya)(ya)降(jiang)至零位,按(an)一下停(ting)止按(an)鈕,高(gao)壓(ya)(ya)(ya)(ya)(ya)、低(di)壓(ya)(ya)(ya)(ya)(ya)輸(shu)出(chu)停(ting)止,然后切斷電源(yuan)。此時應用直(zhi)流(liu)高(gao)壓(ya)(ya)(ya)(ya)(ya)放電棒給被(bei)試(shi)品及(ji)試(shi)驗(yan)裝置(zhi)本身充分放電。

直流泄漏試驗操作過程注意事項

(1)試(shi)驗人(ren)員應做好責任分工,設定好試(shi)驗現場的(de)安(an)全距離,仔(zi)細(xi)檢查好被試(shi)品及試(shi)驗變壓器的(de)接地情況(kuang),并設有(you)專(zhuan)人(ren)監(jian)護安(an)全及觀察被試(shi)品狀(zhuang)態工作(zuo)。
(2)被試(shi)(shi)品(pin)做試(shi)(shi)驗前,應拆除所有對(dui)外連線(xian),并(bing)充(chong)分(fen)放電(dian),主要部位(wei)應清除干凈,保持干燥,以免損壞被試(shi)(shi)品(pin)及帶來(lai)試(shi)(shi)驗數(shu)值的(de)誤差。
(3)對于大容量試品(pin)(電(dian)(dian)容器(qi)、超(chao)長電(dian)(dian)纜等)試驗時(shi)應(ying)緩慢升(sheng)壓,防止被試品(pin)的充(chong)電(dian)(dian)電(dian)(dian)流過大而燒壞微安(an)表,必(bi)要(yao)時(shi)應(ying)分級加壓分別讀取各電(dian)(dian)壓下微安(an)表的穩定讀數(shu)。
(4)試(shi)驗過程中,應(ying)嚴密監(jian)視被試(shi)品、微安表及(ji)試(shi)驗裝置等,一(yi)旦(dan)發生閃爍、擊穿等現象應(ying)立即(ji)降(jiang)壓,切(qie)斷電源(yuan),并查明原因。

五、配(pei)套(tao)選購產品(pin)

下列(lie)產品僅(jin)供選擇,購買時需另行計價(jia)。
1.KZX系列電源控制箱 容量:1KVA-5KVA、輸入電壓:220V
2.
KZT系列電源控制臺 容量:10KVA~300KVA輸入電壓:220V或380V
3.數字微安表:SWB-II
4.高壓濾波電容: 0.01MF、40 ~ 100KV
5.高壓直流放電棒: FBR— 70、140、210KV
6.放電球隙: Q—50、100、150、200、250、500
7.標準試油杯: 400ml
8.折疊式手推車: 150、300型
9.絕緣支架: 50、100、200、300、400KV
10.阻容分壓器: FRC —50、100、150、200KV
11.高壓硅堆: 2DL—150、300、450KV
12.水 電 阻: 50、100

六、主(zhu)要試驗設(she)備的選擇

1、試(shi)驗變壓器
其(qi)高壓側(ce)額定電(dian)(dian)(dian)壓應不(bu)(bu)小于(yu)被試(shi)品的高試(shi)驗電(dian)(dian)(dian)壓,額定電(dian)(dian)(dian)流不(bu)(bu)小于(yu)被試(shi)品的大電(dian)(dian)(dian)容(rong)電(dian)(dian)(dian)流。被試(shi)品的電(dian)(dian)(dian)容(rong)電(dian)(dian)(dian)流和試(shi)驗變壓器所需容(rong)量(liang)計(ji)算式(shi)為:

被試(shi)品電容(rong)量Cx可由交流電橋測出(chu)。常用的被試(shi)品電容(rong)量按表1選取。

幾種常(chang)用被(bei)試品的(de)電(dian)容量(pF) 表1

 

2、調(diao)壓設(she)備
(1)自(zi)藕調(diao)壓(ya)器。其(qi)調(diao)壓(ya)范圍(wei)廣、功率損耗小、波(bo)形畸變(bian)小、選(xuan)擇這種(zhong)調(diao)壓(ya)方式為(wei)(wei)。自(zi)藕調(diao)壓(ya)器的(de)容量(liang)按(an)0.75 ~ 1倍的(de)試(shi)驗變(bian)壓(ya)器的(de)容量(liang)選(xuan)擇,適用于(yu)容量(liang)為(wei)(wei)100KVA以下的(de)試(shi)驗變(bian)壓(ya)器的(de)調(diao)壓(ya)。
(2)感應調壓器。其調壓范圍大,波形畸形小、但結構復雜、價格較貴,當試驗變壓器的容量較大時(如100KVA以上)使用。
3、限流電阻

限流電阻的作用是,當被試品擊穿時,限制斷路電流,從而保護試驗變壓器,防止故障的擴大。其數值以高試驗電壓為準,按0.5 ~ 1 Ω / V(有效值)選擇,限流電阻可用水電阻。注意水不能充滿玻璃管,應留有余地,以防爆裂。
4、放電球隙

放電(dian)(dian)球(qiu)隙(xi)(xi)的布置方式有垂直(zhi)和水平(ping)兩(liang)種,球(qiu)隙(xi)(xi)間距S和球(qiu)的直(zhi)徑D的關(guan)系應(ying)保護在0.05D ≤S ≤0.5D范圍內(nei),球(qiu)隙(xi)(xi)上的水電(dian)(dian)阻阻值一般按0.1 ~ 1Ω/V選取,設置放電(dian)(dian)球(qiu)隙(xi)(xi)的目的是為了對重要的被試品(pin)起(qi)保護作用,可(ke)以將由于(yu)誤操作或被試品(pin)擊穿引起(qi)的過電(dian)(dian)壓(ya)限制(zhi)在允許的范圍內(nei)。

七(qi)、變壓(ya)器技術(shu)指示

型(xing)號

容量(liang)

高壓電(dian)壓

高壓電流

低壓輸入

變比

溫(wen)升℃

(KVA)

(KV)

(mA)

電壓(V)

電流(A)

高/儀

30分鐘(zhong)

YDQC-1.5/50

1.5

50

30

200

7.5

500

10

YDQC-3/50

3

50

60

200

15

500

10

YDQC-5/50

5

50

100

200

25

500

10

YDQC-10/50

10

50

200

200

50

500

10

YDQC-15/50

15

50

300

200

75

500

10

YDQC-20/50

20

50

400

380

53

500

10

YDQC-30/50

30

50

600

380

79

500

10

YDQC-50/50

50

50

1000

380

12

500

10

YDQC-5/100

5

100

50

200

25

1000

10

YDQC-10/100

10

100

100

200

50

1000

10

YDQC-20/100

20

100

200

400

50

1000

10

YDQC-30/100

30

100

300

400

75

1000

10

YDQC-50/100

50

100

500

400

125

1000

10

YDQC-20/150

20

150

133

400

50

1500

10

YDQC-30/150

30

150

200

400

75

1500

10

YDQC-50/150

50

150

333

400

125

1500

10

YDQC-100/150

100

150

667

400

250

1500

10

YDQC-50/200

50

200

250

400

125

2000

10

YDQC-100/200

100

200

500

400

250

2000

10

YDQC-150/200

150

200

750

400

375

2000

10

YDQC-200/200

200

200

1000

400

500

2000

10

YDQC-300/200

300

200

1500

400

600

2000

10

YDQC-50/300

50

300

170

400

125

3000

10

YDQC-100/300

100

300

333

400

250

3000

10

YDQC-150/300

150

300

500

400

375

3000

10

YDQC-200/300

200

300

667

400

500

3000

10

YDQC-300/300

300

300

3000

500

600

3000

10

1、使用環境條件
環境溫度不高于+40℃、不低于—20℃;空氣相對濕度不大于90%;海拔高度不超過2000米;
2、工作電壓
電源控制箱(臺)輸入電壓為工頻220V或380V、相對誤差不超過±10%;(具體使用電壓根據用戶所定試驗變壓器規格選取)
八、隨貨文件

YDQC 系列試驗變壓器產品說明書 1份
產品出廠試驗報告 1份
產品合格證 1份