全自動變壓器變比儀
 

一、LYBBC-III全自動變壓器變比儀產品概述

在電(dian)力(li)變(bian)壓(ya)器(qi)的(de)(de)半成(cheng)品、成(cheng)品生產過程(cheng)中(zhong)(zhong),新安裝的(de)(de)變(bian)壓(ya)器(qi)投入運行之前以及電(dian)力(li)系統(tong)(tong)中(zhong)(zhong)變(bian)壓(ya)器(qi)運行過程(cheng)中(zhong)(zhong)根據(ju)國(guo)家(jia)電(dian)力(li)部的(de)(de)預(yu)防性(xing)試(shi)(shi)(shi)驗規程(cheng)中(zhong)(zhong),要(yao)求對運行的(de)(de)變(bian)壓(ya)器(qi)定期進(jin)行匝(za)數比(bi)或電(dian)壓(ya)比(bi)測(ce)(ce)試(shi)(shi)(shi)。傳統(tong)(tong)的(de)(de)變(bian)比(bi)電(dian)橋操作繁瑣,讀(du)數不直觀,且要(yao)進(jin)行必要(yao)的(de)(de)換算(suan),測(ce)(ce)試(shi)(shi)(shi)結(jie)果只為(wei)(wei)一相(xiang)變(bian)比(bi)的(de)(de)資料(liao)。全自動變(bian)比(bi)測(ce)(ce)試(shi)(shi)(shi)儀克服(fu)了(le)(le)傳統(tong)(tong)變(bian)比(bi)電(dian)橋測(ce)(ce)試(shi)(shi)(shi)的(de)(de)缺(que)點。屏(ping)幕采用一次完成(cheng)三相(xiang)變(bian)比(bi)測(ce)(ce)試(shi)(shi)(shi),測(ce)(ce)試(shi)(shi)(shi)速度快(kuai),準確度高(gao)。大(da)大(da)節省了(le)(le)現場測(ce)(ce)試(shi)(shi)(shi)時間,為(wei)(wei)客戶的(de)(de)試(shi)(shi)(shi)驗帶來了(le)(le)很(hen)高(gao)的(de)(de)效(xiao)率(lv)。

二、LYBBC-III全自動變壓器變比儀安(an)全措(cuo)施

1、使用本儀器前一定(ding)要認真閱讀(du)本操作(zuo)說明書。

2、儀器(qi)的操作(zuo)者應具(ju)備一(yi)般(ban)電氣設(she)備或儀器(qi)的使用常識。

3、本儀器戶內外(wai)均可(ke)使用,但應避開雨淋(lin)、腐(fu)蝕氣體(ti)、塵(chen)埃過濃(nong)、高溫、陽光直射場所(suo)使用。

4、儀表應避免劇烈振動。

5、對儀器的維(wei)修(xiu)、護理和調整應(ying)由專業人員進行。

6、測試線夾的(de)黃(huang)、綠、紅分別對應變壓器的(de)A、B、C不要(yao)接錯。

7、高、低(di)壓電纜不要接反。

8、測(ce)單相變壓(ya)器(qi)時只使用(yong)(yong)(yong)黃(huang)色(se)和綠色(se)線夾,不要用(yong)(yong)(yong)錯,不用(yong)(yong)(yong)的測(ce)試夾要懸空。

三、性能特點

1、測試(shi)量(liang)程寬,高可達(da)10000。

2、測試速度(du)快(kuai),10秒鐘完成三相測試

3、Z形(xing)聯接(jie)變(bian)壓器測試。

4、具有盲測(ce)變比、組別測(ce)試功能(neng)。(盲測(ce)時需知道高壓側連接方式)

5、不掉(diao)電時鐘(zhong)和(he)日期顯示,數據(ju)存儲功能(neng)。

6、高、低壓反接的保(bao)護功(gong)能。

7、變壓器短路、匝間短路保(bao)護功能(neng)。

8、熱敏(min)打(da)印(yin)機輸出功能(neng),快速(su)、無聲。

9、體積小、重(zhong)量輕。

四、技術指標(biao)

1、量程:0.8~10000

2、度:0.1%±2個字(zi)(500以下)

0.2%±2個字(500~2000)

0.3%±2個(ge)字(zi)(2000~4000)

0.5%±2個(ge)字(4000以(yi)上)

3、分辨率:小0.0001

4、輸出(chu)電(dian)壓:160V、10V 自動換檔

5、工作電源:AC220V±10%  50HZ

6、使用溫度:–20℃~ 40℃

7、相對濕度:≤85%,不(bu)結露

五、系統描述

儀器的面(mian)板見圖1

1、顯示屏:240×128點陣液晶(jing),帶LED背(bei)光,顯示操作(zuo)菜單和測試結果(guo)。

2、打(da)印(yin)機:可打(da)印(yin)測試(shi)結果(guo)

3、電源(yuan)(yuan)插(cha)(cha)座(zuo):是(shi)整機電源(yuan)(yuan)輸入口(kou),接220V,50Hz電源(yuan)(yuan),插(cha)(cha)座(zuo)帶保險和開關。

4、:儀器接地柱。

5、高壓(ya)端:高壓(ya)端A、B、C分別通(tong)過(guo)黃(huang)、綠、紅測(ce)試線(xian)與變(bian)壓(ya)器的高壓(ya)A、B、C接線(xian)端相接。

6、低壓(ya)端:低壓(ya)端a、b、c分別通過黃、綠、紅測(ce)試線與變壓(ya)器的低壓(ya)a、b、c接(jie)線端相接(jie)。

7、輝  ;度(du)(du):調(diao)節(jie)顯示器的(de)對比度(du)(du)。

8、功(gong)能(neng)鍵:在顯示(shi)器的右方有(you)F1、F2兩(liang)個功(gong)能(neng)鍵,在儀器操(cao)作(zuo)過(guo)程中按界(jie)面提示(shi)表示(shi)不同的功(gong)能(neng)。

9、復位鍵(jian)(jian):按此鍵(jian)(jian)整(zheng)機(ji)復位回到初(chu)始(shi)狀態(tai)。

10、確(que)認(ren)鍵:按確(que)認(ren)鍵開始(shi)對變(bian)壓器進行測(ce)試。

11、返(fan)回(hui)鍵:返(fan)回(hui)初始界面。

12、向上鍵:向上移動光標,在儀器(qi)的使用過(guo)程中(zhong)根據提示操作。

13、向下鍵:向下移動光標,在儀器的使(shi)用過(guo)程中根據提示操作。

14、向左鍵:向左移動光(guang)標(biao),在儀器的使用過程中根據提示操作。

15、向右鍵:向右移動光標,在(zai)儀器的使用(yong)過(guo)程中根據提示操作(zuo)。

六(liu)、操作方法

1、接線:

根據(ju)被測(ce)試變壓器的具體情況正確(que)聯接(jie)測(ce)試線夾。

a、單(dan)相(xiang)變壓(ya)(ya)器:高(gao)壓(ya)(ya)端電(dian)纜(lan)的黃(huang)(huang)、綠(lv)線夾接被測變壓(ya)(ya)器高(gao)電(dian)壓(ya)(ya)側(ce)(ce)的接線端,低壓(ya)(ya)端電(dian)纜(lan)的黃(huang)(huang)、綠(lv)線夾接被測變壓(ya)(ya)器低電(dian)壓(ya)(ya)側(ce)(ce)的接線端。

b、三相(xiang)(xiang)變壓(ya)器:將高壓(ya)端(duan)和(he)低壓(ya)端(duan)電纜(lan)的3色夾(jia)鉗按(an)黃、綠、紅各對(dui)應高壓(ya)A相(xiang)(xiang)、B相(xiang)(xiang)、C相(xiang)(xiang)和(he)低壓(ya)a相(xiang)(xiang)、b相(xiang)(xiang)、c相(xiang)(xiang)連接。

2、變比測(ce)量:

儀(yi)器接線(xian)完成后(hou),插上(shang)電源線(xian),打開電源開關,屏幕顯示見圖2。

4秒鐘(zhong)后(hou)屏幕顯示(shi)見圖3。

①如果(guo)直接測量變比,此(ci)時可以直接按F1鍵直接進入(ru)測試,顯示“正在測試”,測試結(jie)果(guo)顯示如圖4所(suo)示。

此(ci)時,可以(yi)使用功(gong)能鍵F1、F2分別操作(zuo)儀器(qi)進(jin)行“重測”、“存儲”,如果需(xu)要(yao)打印(yin)可以(yi)按打印(yin)鍵打印(yin)當前顯示(shi)的數(shu)據,當選擇存儲時儀器(qi)內部可以(yi)存儲50組數(shu)據。

②如果需要改(gai)變參數,在圖2所示主(zhu)菜單按下F2鍵(jian),則屏幕(mu)顯示見圖5。

向(xiang)左向(xiang)右鍵按下,光(guang)標可以(yi)在各個參數(shu)之間(jian)上下循環移動(dong),可將光(guang)標移動(dong)到需要改變(bian)的參數(shu)上;

向上(shang)向下鍵(jian)按(an)下,圖5的(de)狀態可(ke)以(yi)改變(bian)高壓方式(shi),選(xuan)擇項目(mu)包(bao)括“Y”、“D”、“單”、“Z”,可(ke)以(yi)循環(huan)選(xuan)擇,選(xuan)擇“單”,測試時可(ke)以(yi)測量單相變(bian)壓器或PT;光標在其他位置(zhi)時可(ke)以(yi)改變(bian)數字的(de)大(da)小;

返回鍵按下(xia),菜單返回到開機初始菜單;測(ce)試(shi)單相變壓(ya)器時,結果(guo)顯(xian)示(shi)如圖4所(suo)示(shi),如果(guo)選(xuan)擇三(san)相測(ce)試(shi)時,測(ce)試(shi)結果(guo)如圖6所(suo)示(shi)。

③如果調閱儀器內部存儲的歷(li)史數據,在開機初始(shi)菜單下(xia)按下(xia)“F2”鍵,數據顯示如圖7所示。

按向上(shang)向下鍵(jian)改變選擇的記錄號,按F1鍵(jian)清除當前記錄,按F2鍵(jian)清除全部(bu)記錄。

3、時間(jian)設置:在開機圖3界面下,按返回鍵,屏(ping)幕顯示如下 :

此時按向上(shang)向下鍵(jian)修改(gai)(gai)當前數(shu)值,按向左(zuo)向右鍵(jian)使光(guang)標左(zuo)右移動(dong),改(gai)(gai)變所需修改(gai)(gai)的時間(jian)。修改(gai)(gai)結束(shu)后(hou)按確認鍵(jian)退出。

七(qi)、操作(zuo)示(shi)例

1.Y-d-11,電壓組(zu)合110±8×1.25%/10.5KV 的(de)變壓器(qi)。

按圖(tu)9進行接線。

打開電源開關顯(xian)示(shi)出(chu)主菜單(見(jian)圖(tu)3),此(ci)時(shi)按(an)確認鍵,顯(xian)示(shi)見(jian)圖(tu)5。此(ci)時(shi)可輸入額定變比(bi)值,按(an)照變壓(ya)器(qi)銘牌上的高壓(ya)端9分(fen)接電壓(ya)值110.0,低壓(ya)電壓(ya)10.5,計算出(chu)額定變比(bi)10.476,輸入額定變比(bi)10.476,分(fen)接總數09,分(fen)接間距(ju)1.25%,輸入完成后,按(an)返(fan)回(hui)鍵返(fan)回(hui)到主菜單,按(an)F1鍵,儀器(qi)開始測量,測量結果見(jian)圖(tu)10所示(shi)。

此時(shi),可按(an)F1鍵(jian)(jian)重測一次,F2鍵(jian)(jian)存儲數據,打印鍵(jian)(jian)打印數據,按(an)復位鍵(jian)(jian)返(fan)回主菜單。

2.單相變壓器,電壓組(zu)合525/√3±8×1.25%/20,按圖(tu)11接線。

打開(kai)(kai)電源(yuan)開(kai)(kai)關(guan),顯示主菜單(見圖3),操作與上例相似,只是額定變比的計算(suan)要注意,變壓(ya)(ya)器銘牌高(gao)壓(ya)(ya)端(duan)9分(fen)接電壓(ya)(ya)值(525/1.732=)303.1,低壓(ya)(ya)側電壓(ya)(ya)20,計算(suan)值是303.1/20=15.155,輸入到額定變比位置(zhi),在參數設置(zhi)時(shi),將(jiang)高(gao)壓(ya)(ya)方(fang)式改成(cheng)“單”,然后進(jin)行測試(shi)。測試(shi)結果與圖4相似。

八、儀器(qi)成套(tao)性(xing)

名稱

數量(liang)

主機

一(yi)臺

測試(shi)電(dian)纜

一套

三芯電源線(xian)

一條

使用(yong)說明書

一本(ben)

合格(ge)證/保修(xiu)卡

一張(zhang)

保(bao)險管(guan)(2A)

兩個

打印(yin)紙

兩卷

裝箱單

一張(zhang)

九、注(zhu)意事(shi)項(xiang)

1、有載(zai)分(fen)接(jie)開關19檔的變壓器,9、10、11分(fen)接(jie)是同(tong)一個值,儀(yi)器輸入分(fen)接(jie)類型時(shi)應輸入17,此(ci)時(shi)12分(fen)接(jie)以后,儀(yi)器顯示分(fen)接(jie)位(wei)置(zhi)比實際(ji)位(wei)置(zhi)小2。

2、本儀器(qi)分(fen)(fen)接位置(zhi)的設置(zhi)按高壓側調(diao)壓設計,是假設1分(fen)(fen)接為高電(dian)壓檔位,如果電(dian)壓反(fan)向設計或分(fen)(fen)接開(kai)關在低壓側的變壓器(qi),顯示分(fen)(fen)接位置(zhi)和實際分(fen)(fen)接位置(zhi)倒置(zhi)。

十、售后服務

自購買之日起12個月內,屬產品質量問題免費包(bao)修。終身提(ti)供保修和技術服務。如發現儀(yi)器有不(bu)正(zheng)常情況或故障(zhang)請與本公司及(ji)時(shi),以便(bian)(bian)為您安排便(bian)(bian)捷的處理方(fang)案。

概(gai)述(shu)

是變(bian)壓(ya)器停電檢(jian)修的必測(ce)(ce)項目,要完成(cheng)上述檢(jian)測(ce)(ce)就需要分(fen)別配(pei)置變(bian)壓(ya)器直(zhi)流電阻測(ce)(ce)試(shi)(shi)(shi)儀(yi)及變(bian)壓(ya)器變(bian)比(bi)(bi)組(zu)別測(ce)(ce)試(shi)(shi)(shi)儀(yi),但上述兩種儀(yi)器生產廠(chang)家較多,且功能操作及配(pei)線都(dou)不(bu)相(xiang)同,而且每次試(shi)(shi)(shi)驗時都(dou)需要攜(xie)帶兩種儀(yi)器,由(you)于(yu)兩種儀(yi)器的功能不(bu)同,還(huan)需要進(jin)行兩次測(ce)(ce)試(shi)(shi)(shi)準備(bei)工(gong)作及兩次接線拆(chai)線,這(zhe)樣一來導致工(gong)作效率大(da)大(da)降低。變(bian)壓(ya)器直(zhi)流電阻變(bian)比(bi)(bi)測(ce)(ce)試(shi)(shi)(shi)儀(yi)解(jie)決了(le)上述問題,一臺(tai)儀(yi)器可進(jin)行兩項測(ce)(ce)試(shi)(shi)(shi):直(zhi)阻測(ce)(ce)試(shi)(shi)(shi)和變(bian)比(bi)(bi)測(ce)(ce)試(shi)(shi)(shi)。屏(ping)幕采用大(da)屏(ping)幕高分(fen)辨率液晶顯示(shi)屏(ping),方(fang)便現場使用,具有中文(wen)菜單(dan)提示(shi)功能,操作簡(jian)便直(zhi)觀,一次完成(cheng)三相(xiang)直(zhi)阻測(ce)(ce)試(shi)(shi)(shi)、三相(xiang)變(bian)比(bi)(bi)測(ce)(ce)試(shi)(shi)(shi),測(ce)(ce)試(shi)(shi)(shi)速(su)度(du)快(kuai),準確度(du)高。

??性能特點  

2.1 直阻變比(bi)測(ce)試(shi)功(gong)能:同時具有直阻測(ce)試(shi)和變比(bi)組(zu)別測(ce)試(shi)功(gong)能,一次接線,完(wan)成兩種測(ce)試(shi),簡單方便。

2.2 變比測試(shi)(shi):具有全三相(xiang)正弦逆變電源(yuan)輸出,輸出電壓自(zi)動調節,具有軟啟、軟停功能,因此測試(shi)(shi)速度快、精度高。

2.3 變(bian)比測試:三相變(bian)壓器、單相變(bian)壓器、PT、Z型變(bian)壓器變(bian)比、組別、極(ji)性測試功(gong)能。

2.4 變(bian)比(bi)測試(shi):具有盲(mang)測功(gong)能,即在不知(zhi)道高、低(di)壓聯結方式時進(jin)行變(bian)比(bi)、組別測試(shi)。

2.5 變(bian)比測試(shi):CT變(bian)比極性測試(shi)功能。

2.6 變比測(ce)試(shi):單相測(ce)試(shi)時(shi)具(ju)有(you)角差測(ce)試(shi)功(gong)能。

2.7 變比(bi)測試(shi):分(fen)接(jie)檔位*高可測試(shi)到(dao)197檔。

2.8 變(bian)比測(ce)試(shi):測(ce)試(shi)量程(cheng)寬,*高可(ke)達10000。

2.9 變比測(ce)試:高低壓反(fan)接保護功能。

2.10 變比測試:輸出短(duan)路保(bao)護功能。

2.11直阻(zu)測試:對(dui)于(yu)星(xing)型接(jie)法且具有中性點引出線的繞組測試,儀器可以采取三(san)相同時(shi)測量的方式測試A0、B0、C0相的電(dian)阻(zu),節省測試時(shi)間。

2.12直(zhi)阻(zu)測(ce)試:對(dui)于Y型和△型的繞組(zu)測(ce)試,儀器可進行(xing)三相自(zi)動測(ce)試,并折算(suan)出三相不平衡率。

2.13直(zhi)阻測試:具有反電動勢保(bao)護、斷線保(bao)護、斷電保(bao)護等多種保(bao)護功能。

2.14直(zhi)阻測試:測量范(fan)圍寬,精度高。

2.15不掉電時鐘和日期顯示;數(shu)據(ju)(ju)存(cun)儲(chu)(chu)方式分(fen)為本(ben)機存(cun)儲(chu)(chu)和優盤(pan)(pan)存(cun)儲(chu)(chu),其中本(ben)機存(cun)儲(chu)(chu)可存(cun)儲(chu)(chu)測(ce)試數(shu)據(ju)(ju)600條(直阻測(ce)試300條、變比測(ce)試300條),并且本(ben)機存(cun)儲(chu)(chu)可轉存(cun)至優盤(pan)(pan);優盤(pan)(pan)存(cun)儲(chu)(chu)數(shu)據(ju)(ju)格式為Word格式,可直接(jie)在電腦(nao)上(shang)編輯打印。

2.16 熱敏打(da)印機打(da)印功(gong)能,快(kuai)速、無聲。

體(ti)積小、重量輕,方便(bian)攜帶使(shi)用。

3 技術(shu)指(zhi)標

3.1 變比測試(shi)

3.1.1 量程:0.9~10000

3.1.2 準確度:±;(讀數×0.1%+2字(zi))(小于等(deng)于500)          

±(讀數×0.2%+2字)(大(da)于500小于等于3000)

±(讀數×0.3%+2字)(大于3000)

3.1.3 分辨(bian)率(lv):0.9~9.9999(0.0001)      100~999.99(0.01)  10000及以上(1)

10~99.999(0.001)          1000~9999.9(0.1)

直阻測試

3.2.1 量(liang)程:10A      1.000mΩ~1Ω     1  A      100.0mΩ~20Ω

5 A      10.00mΩ~4Ω      0.2A     1.000 Ω~100Ω

5A +5A  10.00mΩ~1Ω     0.2A+0.2A  1.000 Ω~50Ω

1A +1A  100.0mΩ~5Ω

3.2.2 準確度:±(讀(du)數×0.2%+2字(zi))

3.2.3 *高分辨率:0.01uΩ

3.3 工作電源:AC220V±10%, 50/60Hz

3.4 使用溫度:-10℃~50℃   相對(dui)濕度:<90%,不(bu)結露

3.5儀器(qi)體(ti)積(ji):390mm×280mm×190mm

3.6儀器重(zhong)量:9kg(不包括測試線(xian))

4 面板及接線端子(zi)介紹(shao)

4.1 高(gao)壓測試(shi)端:黃、綠、紅、黑(hei)(hei)(hei)4色接(jie)線(xian)座(zuo),分別對應A、B、C、O三相(xiang),和高(gao)壓測試(shi)線(xian)(較長,黃、綠、紅、黑(hei)(hei)(hei))棒彈側對應連接(jie),測試(shi)線(xian)另一端有黃、綠、紅、黑(hei)(hei)(hei)4色測試(shi)鉗(qian)(qian),對應接(jie)被測變(bian)壓器高(gao)壓側的A、B、C、O套(tao)管(guan)(如無(wu)中性點O套(tao)管(guan),將黑(hei)(hei)(hei)色測試(shi)鉗(qian)(qian)懸(xuan)空即(ji)可)。

4.2 低(di)壓(ya)測(ce)試端:黃、綠(lv)、紅3色(se)(se)接線座(zuo),分別對應(ying)(ying)a、b、c三相,和低(di)壓(ya)測(ce)試線(較短,黃、綠(lv)、紅)棒彈側對應(ying)(ying)連接,測(ce)試線另一端有黃、綠(lv)、紅3色(se)(se)測(ce)試鉗,對應(ying)(ying)接被測(ce)變(bian)壓(ya)器(qi)低(di)壓(ya)側的a、b、c套管。

4.3 顯(xian)示屏:    320×240點陣液晶,帶LED背光,顯(xian)示操作菜單和(he)測(ce)試結果。

4.4 按鍵:      操作(zuo)儀(yi)器用。 “↑↓”為(wei)“上下”鍵,選擇(ze)移動或(huo)修(xiu)改數據(ju);“←→”為(wei)“左右(you)”鍵,選擇(ze)移動或(huo)修(xiu)改數據(ju);“確(que)認(ren)”鍵,確(que)認(ren)當(dang)(dang)前(qian)操作(zuo);“取消”鍵,放棄當(dang)(dang)前(qian)操作(zuo)。

4.5 優盤(pan)接口:  外接優盤(pan)用,用來存儲測試數據,請使用FAT或FAT32格式(shi)的U盤(pan)。在存儲過程中,嚴禁撥出優盤(pan)。

4.6 RS232:     儀器升級用。

4.7 打印(yin)(yin)機:    ;打印(yin)(yin)測試結果(guo)。

4.8 接地端(duan)子(zi):  儀(yi)器必(bi)須(xu)可(ke)靠(kao)接地。現場接地點可(ke)能有油漆或銹蝕(shi),必(bi)須(xu)清理干凈(jing)。

4.9 電(dian)源(yuan)(yuan)開(kai)關: 整機電(dian)源(yuan)(yuan)開(kai)關和電(dian)源(yuan)(yuan)插座,保(bao)(bao)險管座與電(dian)源(yuan)(yuan)插座一體,保(bao)(bao)險管規格為250V/3A,尺(chi)寸φ5mm×20mm,應使用相同規格的保(bao)(bao)險管。

5 操作使用(yong)說明

5.1 測(ce)試接線

根據被試(shi)(shi)試(shi)(shi)品(pin)的(de)情況正確連接測試(shi)(shi)線。

5.1.1 變比測(ce)試接線(只測(ce)變比項(xiang)目試驗(yan))

5.1.1.1單(dan)相變(bian)壓器或單(dan)相PT測(ce)試接線(xian)

高壓(ya)測(ce)(ce)(ce)試(shi)(shi)(shi)(shi)端(duan)測(ce)(ce)(ce)試(shi)(shi)(shi)(shi)線(xian)(較長)的黃、綠測(ce)(ce)(ce)試(shi)(shi)(shi)(shi)鉗(qian)接被測(ce)(ce)(ce)試(shi)(shi)(shi)(shi)品的高壓(ya)端(duan);低壓(ya)測(ce)(ce)(ce)試(shi)(shi)(shi)(shi)端(duan)測(ce)(ce)(ce)試(shi)(shi)(shi)(shi)線(xian)(較短)的黃、綠測(ce)(ce)(ce)試(shi)(shi)(shi)(shi)鉗(qian)接被測(ce)(ce)(ce)試(shi)(shi)(shi)(shi)品的低壓(ya)端(duan)。

5.1.1.2單相CT測(ce)試接線(xian)

高壓(ya)測(ce)試(shi)(shi)端測(ce)試(shi)(shi)線(較長)的(de)黃(huang)、綠測(ce)試(shi)(shi)鉗接(jie)被測(ce)試(shi)(shi)品的(de)二次側;低壓(ya)測(ce)試(shi)(shi)端測(ce)試(shi)(shi)線(較短)的(de)黃(huang)、綠測(ce)試(shi)(shi)鉗接(jie)被測(ce)試(shi)(shi)品的(de)一次側。

5.1.1.3三相變壓器測試(shi)接線

高(gao)壓(ya)測(ce)(ce)試(shi)(shi)(shi)端測(ce)(ce)試(shi)(shi)(shi)線(較(jiao)長(chang))的(de)(de)黃、綠(lv)、紅測(ce)(ce)試(shi)(shi)(shi)鉗接(jie)(jie)被測(ce)(ce)試(shi)(shi)(shi)品高(gao)壓(ya)端的(de)(de)A、B、C套(tao)管(guan);低壓(ya)測(ce)(ce)試(shi)(shi)(shi)端測(ce)(ce)試(shi)(shi)(shi)線(較(jiao)短)的(de)(de)黃、綠(lv)、紅測(ce)(ce)試(shi)(shi)(shi)鉗接(jie)(jie)被測(ce)(ce)試(shi)(shi)(shi)品低壓(ya)端的(de)(de)a、b、c套(tao)管(guan)。

5.1.2 直阻測試(shi)接(jie)線(只測直阻項目試(shi)驗)

高壓(ya)測(ce)(ce)試端測(ce)(ce)試線(較(jiao)長)的(de)(de)黃、綠(lv)(lv)、紅、黑測(ce)(ce)試鉗(qian)接被測(ce)(ce)試品高壓(ya)端的(de)(de)A、B、C、O套(tao)管(guan)(如無(wu)中性(xing)點O套(tao)管(guan),將黑色(se)測(ce)(ce)試鉗(qian)懸(xuan)空(kong)即可)。;低壓(ya)測(ce)(ce)試端測(ce)(ce)試線(較(jiao)短(duan))的(de)(de)黃、綠(lv)(lv)、紅測(ce)(ce)試鉗(qian)接被測(ce)(ce)試品低壓(ya)端的(de)(de)a、b、c套(tao)管(guan)。

5.1.3 直阻(zu)+變比測(ce)試接線

    同直阻測(ce)試接線。

5.2 打印(yin)機(ji)使(shi)用說明(ming)

打印機(ji)(ji)按鍵和(he)打印機(ji)(ji)指(zhi)示燈(deng)(deng)是一(yi)體式(shi)。打印機(ji)(ji)上電后,正常(chang)時指(zhi)示燈(deng)(deng)為常(chang)亮,缺紙(zhi)時指(zhi)示燈(deng)(deng)閃爍。按一(yi)次按鍵,打印機(ji)(ji)走(zou)紙(zhi)。                                         

打印(yin)機自檢:按住按鍵不放,同時給(gei)打印(yin)機上電,即打印(yin)出自檢條(tiao)。

打(da)(da)印(yin)機(ji)換紙(zhi)(zhi):扣出(chu)旋(xuan)轉扳手,打(da)(da)開(kai)紙(zhi)(zhi)倉蓋(gai);把打(da)(da)印(yin)紙(zhi)(zhi)裝入,并(bing)(bing)拉出(chu)一(yi)截(jie)(超出(chu)一(yi)點撕紙(zhi)(zhi)牙(ya)齒),注意把紙(zhi)(zhi)放(fang)整齊,紙(zhi)(zhi)的方向(xiang)(xiang)為有藥液一(yi)面(光滑面)向(xiang)(xiang)上(shang);合上(shang)紙(zhi)(zhi)倉蓋(gai),打(da)(da)印(yin)頭走紙(zhi)(zhi)軸(zhou)壓(ya)(ya)齊打(da)(da)印(yin)紙(zhi)(zhi)后稍用力把打(da)(da)印(yin)頭走紙(zhi)(zhi)軸(zhou)壓(ya)(ya)回打(da)(da)印(yin)頭,并(bing)(bing)把旋(xuan)轉扳手推入復(fu)位。

5.3 使用操作

所有測試(shi)線接好以后,打開電(dian)源開關,儀器初始(shi)化后進入“主菜單”屏(見圖二)。

此(ci)時(shi)(shi)頂(ding)欄(lan)顯(xian)示(shi)儀器(qi)運(yun)行時(shi)(shi)間,中間顯(xian)示(shi)儀器(qi)型號、廠(chang)家信息(xi)、功能(neng)選項,底(di)部顯(xian)示(shi)軟(ruan)件版本號和儀器(qi)編號。

按(an)“上(shang)下”、“左右(you)”鍵選(xuan)擇相應功能(neng)選(xuan)項,按(an)“確(que)認”鍵進入所選(xuan)功能(neng)菜單。

5.3.1 變比(bi)測試

三相測試:普(pu)通三相變壓器(qi)測試。

單相測試:單相變壓器、PT、CT測試。

Z 型(xing)測試:Z型(xing)變壓器測試。

5.3.1.1 三相測(ce)試

在“主菜單”屏(ping)下選(xuan)中(zhong)“變比(bi)測(ce)試”項后,按(an)“確(que)認(ren)”鍵進入“變比(bi)測(ce)試選(xuan)擇”屏(ping)(見圖三)。

在“變比測(ce)試(shi)選(xuan)擇”屏(ping)下選(xuan)中(zhong)“三相測(ce)試(shi)”項后,按“確認”鍵進入“三相測(ce)試(shi)選(xuan)擇”屏(ping)(見圖(tu)四)。

正(zheng)常測試:已知(zhi)高、低(di)壓(ya)聯(lian)結方式的情(qing)況下,正(zheng)確輸入高、低(di)壓(ya)聯(lian)結方式后進行測試。

盲(mang)測(ce)功能:在不知道(dao)高、低壓聯結方式及組別(bie)時可以準確測(ce)出變比和組別(bie)。

“正常測(ce)(ce)試”和“盲(mang)測(ce)(ce)功(gong)(gong)能(neng)”的(de)設(she)置、操作類(lei)似(si),在此以“盲(mang)測(ce)(ce)功(gong)(gong)能(neng)”為例(li)進行說明介紹。選(xuan)擇“盲(mang)測(ce)(ce)功(gong)(gong)能(neng)”項后,按“確認”鍵進入“盲(mang)測(ce)(ce)功(gong)(gong)能(neng)參數(shu)設(she)置”屏(見(jian)圖五)。

“額(e)定(ding)高壓(ya)”、“額(e)定(ding)低壓(ya)”、“分(fen)接”、“聯結(jie)組別”、“試(shi)(shi)品編(bian)號”、“測試(shi)(shi)”為(wei)菜(cai)單(dan)選(xuan)項(xiang)(xiang)(xiang),其(qi)右邊(bian)所屬(shu)各項(xiang)(xiang)(xiang)為(wei)功能(neng)(neng)參(can)數。“說明”部分(fen)是對所選(xuan)功能(neng)(neng)的解釋說明。當菜(cai)單(dan)選(xuan)項(xiang)(xiang)(xiang)被選(xuan)中(zhong)(zhong)時(shi),按(an)“上下”鍵(jian)選(xuan)擇不同菜(cai)單(dan)功能(neng)(neng),按(an)“左(zuo)右”鍵(jian)選(xuan)擇菜(cai)單(dan)選(xuan)項(xiang)(xiang)(xiang)所屬(shu)功能(neng)(neng)參(can)數,當菜(cai)單(dan)選(xuan)項(xiang)(xiang)(xiang)所屬(shu)功能(neng)(neng)參(can)數被選(xuan)中(zhong)(zhong)時(shi),按(an)“上下”鍵(jian)修改參(can)數,按(an)“確認(ren)”鍵(jian)或“取(qu)消”鍵(jian)返回(hui)菜(cai)單(dan)選(xuan)項(xiang)(xiang)(xiang)。

額(e)定高(gao)(gao)壓(ya)、額(e)定低(di)(di)壓(ya):設置所測試品的額(e)定高(gao)(gao)、低(di)(di)電(dian)(dian)壓(ya)值。高(gao)(gao)、低(di)(di)電(dian)(dian)壓(ya)值可以(yi)按實(shi)(shi)(shi)際(ji)電(dian)(dian)壓(ya)值輸(shu)(shu)入(ru),也可以(yi)根據實(shi)(shi)(shi)際(ji)情況按實(shi)(shi)(shi)際(ji)比(bi)例關系輸(shu)(shu)入(ru)。只(zhi)有額(e)定高(gao)(gao)、低(di)(di)電(dian)(dian)壓(ya)值、分(fen)(fen)接間距(ju)、額(e)定分(fen)(fen)接位(wei)(wei)輸(shu)(shu)入(ru)正確后,測試結果才(cai)可以(yi)正確計算出當(dang)前分(fen)(fen)接檔位(wei)(wei)值和誤差(cha)值。

分(fen)接:設置所測試品(pin)的分(fen)接間距和額(e)定(ding)分(fen)接位(wei),對于沒有分(fen)接位(wei)的試品(pin),額(e)定(ding)分(fen)接位(wei)輸入00或01即可。

聯(lian)(lian)結(jie)(jie)(jie)組別:設置所測試品的(de)聯(lian)(lian)結(jie)(jie)(jie)方(fang)式(shi)(shi)和聯(lian)(lian)結(jie)(jie)(jie)組別。對(dui)于聯(lian)(lian)結(jie)(jie)(jie)方(fang)式(shi)(shi),高壓側(ce)可(ke)(ke)(ke)以實(shi)(shi)現“Y→D→未(wei)(wei)知(zhi)(zhi)”之(zhi)(zhi)間的(de)循(xun)環轉換(huan),Y表(biao)(biao)示(shi)星形聯(lian)(lian)結(jie)(jie)(jie),D表(biao)(biao)示(shi)三角形聯(lian)(lian)結(jie)(jie)(jie), “未(wei)(wei)知(zhi)(zhi)”表(biao)(biao)示(shi)不清(qing)楚高壓側(ce)聯(lian)(lian)結(jie)(jie)(jie)方(fang)式(shi)(shi),由(you)(you)儀器(qi)自動(dong)(dong)判(pan)斷;低(di)壓側(ce)可(ke)(ke)(ke)以實(shi)(shi)現“y→d→未(wei)(wei)知(zhi)(zhi)”之(zhi)(zhi)間的(de)循(xun)環轉換(huan),y表(biao)(biao)示(shi)星形聯(lian)(lian)結(jie)(jie)(jie),d表(biao)(biao)示(shi)三角形聯(lian)(lian)結(jie)(jie)(jie),“未(wei)(wei)知(zhi)(zhi)”表(biao)(biao)示(shi)不清(qing)楚低(di)壓側(ce)聯(lian)(lian)結(jie)(jie)(jie)方(fang)式(shi)(shi),由(you)(you)儀器(qi)自動(dong)(dong)判(pan)斷。當用戶(hu)(hu)選(xuan)擇已知(zhi)(zhi)的(de)聯(lian)(lian)結(jie)(jie)(jie)方(fang)式(shi)(shi)后,儀器(qi)測量(liang)與顯(xian)示(shi)按用戶(hu)(hu)輸(shu)入為準,當用戶(hu)(hu)選(xuan)擇“未(wei)(wei)知(zhi)(zhi)”后,由(you)(you)儀器(qi)自動(dong)(dong)判(pan)斷聯(lian)(lian)結(jie)(jie)(jie)方(fang)式(shi)(shi),如(ru)果(guo)高、低(di)壓側(ce)的(de)聯(lian)(lian)結(jie)(jie)(jie)方(fang)式(shi)(shi)都選(xuan)擇“未(wei)(wei)知(zhi)(zhi)”時,測量(liang)結(jie)(jie)(jie)果(guo)不顯(xian)示(shi)聯(lian)(lian)結(jie)(jie)(jie)方(fang)式(shi)(shi)。對(dui)于聯(lian)(lian)結(jie)(jie)(jie)組別,用戶(hu)(hu)可(ke)(ke)(ke)按實(shi)(shi)際情況進行選(xuan)擇,如(ru)果(guo)聯(lian)(lian)結(jie)(jie)(jie)組別未(wei)(wei)知(zhi)(zhi),可(ke)(ke)(ke)選(xuan)“自動(dong)(dong)”,由(you)(you)儀器(qi)自動(dong)(dong)判(pan)斷聯(lian)(lian)結(jie)(jie)(jie)組別,在(zai)“盲(mang)測功能”菜單里(li),聯(lian)(lian)結(jie)(jie)(jie)組別固(gu)定為“自動(dong)(dong)”,不可(ke)(ke)(ke)改動(dong)(dong)。

試品編號:設(she)置(zhi)本次(ci)試驗的(de)試品編號。

測試:選(xuan)擇不同(tong)的測量方式(shi)。

三相(xiang)變比:根據設定的高、低壓聯結方式(shi)和(he)聯結組別,三相(xiang)同時測量(liang)變比。

組別(bie)(bie)測(ce)試:只測(ce)量聯結(jie)組別(bie)(bie)。

三(san)相(xiang)AB、三(san)相(xiang)BC、三(san)相(xiang)CA:根據設定(ding)的高、低壓聯(lian)結(jie)方式(shi)和(he)聯(lian)結(jie)組別,只針(zhen)對所

選相進(jin)行(xing)變比測量(liang),此(ci)功能方便只針(zhen)對某一相進(jin)行(xing)測量(liang)、檢測,節約時間(jian)。

參(can)數設置完成(cheng)后,選中(zhong)(zhong)“測試(shi)”項后按“確(que)認”鍵開始測量。在測試(shi)過程中(zhong)(zhong),儀(yi)器如果檢測到短路、高低壓(ya)反接故障時,彈(dan)出(chu)故障提(ti)示框報警,并停(ting)止測量。

“三相變比測(ce)試結果”屏見圖(tu)六。

屏幕中間顯(xian)示(shi)測量結(jie)果,底部顯(xian)示(shi)可(ke)操作(zuo)菜單:

繼續(xu)測試(shi):按設置(zhi)好的參數繼續(xu)測量(liang)。

結(jie)果(guo)打印:將測試結(jie)果(guo)進行打印。

結(jie)果存儲(chu):將測試結(jie)果存儲(chu)到(dao)(dao)本機或(huo)存儲(chu)到(dao)(dao)優盤。

“左右(you)”鍵選(xuan)擇菜單項,“確(que)認”鍵執(zhi)行當前選(xuan)項。

5.3.1.2 單相測試(shi)

在“變比測(ce)試選擇”屏下選中(zhong)“單相(xiang)測(ce)試”項后,按“確認”鍵(jian)進入“單相(xiang)測(ce)試參數設置”屏(見圖(tu)七(qi))。

該屏(ping)設置操作和“盲測功能參數設置”屏(ping)類似。

額定高(gao)(gao)壓(ya)、額定低(di)壓(ya):設置所測(ce)試品(pin)的(de)額定高(gao)(gao)、低(di)電(dian)壓(ya)值(zhi)。高(gao)(gao)、低(di)電(dian)壓(ya)值(zhi)可(ke)(ke)以按實際(ji)電(dian)壓(ya)值(zhi)輸入(ru),也可(ke)(ke)以根據實際(ji)情況按實際(ji)比(bi)例(li)關(guan)(guan)系(xi)輸入(ru)。當選(xuan)擇“單相CT”測(ce)試后,高(gao)(gao)、低(di)電(dian)壓(ya)值(zhi)代表(biao)CT的(de)一次(ci)(ci)側(ce)額定電(dian)流值(zhi)和二次(ci)(ci)側(ce)額定電(dian)流值(zhi),可(ke)(ke)以按實際(ji)電(dian)流輸入(ru),也可(ke)(ke)以根據實際(ji)情況按實際(ji)比(bi)例(li)關(guan)(guan)系(xi)輸入(ru)。

分(fen)接:設置所測試品的分(fen)接間(jian)距。

額定分(fen)接(jie):設置所測試(shi)品(pin)的(de)額定分(fen)接(jie)位(wei)(wei),對于沒有分(fen)接(jie)位(wei)(wei)的(de)試(shi)品(pin),額定分(fen)接(jie)位(wei)(wei)輸入(ru)00或(huo)01即(ji)可。

試品編號:設置(zhi)本次試驗(yan)的試品編號。

測試:選擇不(bu)同的測量方式。

單相PT:根(gen)據設置的參數對(dui)PT進行(xing)變比極性測量(liang)。

單相(xiang)CT:根據設置的(de)參(can)數對CT進行變比(bi)極(ji)性(xing)測量。

單(dan)相變壓器:根據設置的(de)參數對單(dan)相變壓器進行變比極性(xing)測量。

以“單(dan)相(xiang)PT”測試為例,當進行完(wan)“參數設置”后,按(an)“確(que)認”鍵開始測試。在測試過程中,儀器如(ru)果檢測到短路、高低壓反(fan)接故障時,彈出故障提示框(kuang)報警,并(bing)停止(zhi)測量。

“單相(xiang)PT測試結果”屏(見圖八)。

操作(zuo)和(he)“三相變(bian)比測(ce)試結果(guo)”屏類似。

5.3.1.3 Z型測試

“Z型測試”和“三(san)相測試”設置(zhi)、操作(zuo)類似(si),具體操作(zuo)可參(can)考(kao)“三(san)相測試”的(de)相關操作(zuo),在此不多作(zuo)贅述。

5.3.2 直阻測試(shi)

5.3.2.1直阻參數設置

在(zai)“主菜單”屏下選中“直阻測試”項后,按“確認”鍵進入參數設置屏(見圖九)。

“測(ce)試(shi)(shi)繞組”、“測(ce)試(shi)(shi)相別”、“測(ce)試(shi)(shi)溫度”、“折算溫度”、“試(shi)(shi)品(pin)編(bian)號(hao)”、“測(ce)試(shi)(shi)”為菜單選(xuan)(xuan)(xuan)項(xiang),其右邊(bian)所(suo)屬(shu)各項(xiang)為功(gong)(gong)能參數(shu)(shu)。“說明(ming)”部(bu)分是對所(suo)選(xuan)(xuan)(xuan)功(gong)(gong)能的解(jie)釋說明(ming)。當菜單選(xuan)(xuan)(xuan)項(xiang)被選(xuan)(xuan)(xuan)中(zhong)時,按“上下”鍵(jian)(jian)選(xuan)(xuan)(xuan)擇不同菜單功(gong)(gong)能,按“左右”鍵(jian)(jian)選(xuan)(xuan)(xuan)擇菜單選(xuan)(xuan)(xuan)項(xiang)所(suo)屬(shu)功(gong)(gong)能參數(shu)(shu),當菜單選(xuan)(xuan)(xuan)項(xiang)所(suo)屬(shu)功(gong)(gong)能參數(shu)(shu)被選(xuan)(xuan)(xuan)中(zhong)時,按“上下”鍵(jian)(jian)修改參數(shu)(shu),按“確認”鍵(jian)(jian)或“取消”鍵(jian)(jian)返回菜單選(xuan)(xuan)(xuan)項(xiang)。

測試(shi)繞組:選(xuan)擇需(xu)要測試(shi)的試(shi)品繞組,可(ke)(ke)選(xuan)高、中、低壓,繞組材(cai)料可(ke)(ke)選(xuan)銅、鋁(lv)。繞組材(cai)料關系(xi)到電阻折(zhe)(zhe)算值所用的折(zhe)(zhe)算系(xi)數

測(ce)試(shi)相(xiang)(xiang)別(bie):選(xuan)(xuan)擇測(ce)試(shi)試(shi)品的單(dan)(dan)*相(xiang)(xiang)阻(zu)值(zhi)或三相(xiang)(xiang)阻(zu)值(zhi),高壓、中(zhong)壓繞組可選(xuan)(xuan)“單(dan)(dan)相(xiang)(xiang)AO”、“單(dan)(dan)相(xiang)(xiang)BO”、“單(dan)(dan)相(xiang)(xiang)CO”、“單(dan)(dan)相(xiang)(xiang)AB”、“單(dan)(dan)相(xiang)(xiang)BC”、“單(dan)(dan)相(xiang)(xiang)CA”、“三相(xiang)(xiang)同測(ce)Yn”(“三相(xiang)(xiang)同測(ce)Yn”是指變壓器(qi)星型接法帶中(zhong)性點引出線繞組的三相(xiang)(xiang)測(ce)試(shi))、“三相(xiang)(xiang)同測(ce)Y”和“三相(xiang)(xiang)同測(ce)△”;低壓繞組可選(xuan)(xuan)“單(dan)(dan)相(xiang)(xiang)ab”、“單(dan)(dan)相(xiang)(xiang)bc”、“單(dan)(dan)相(xiang)(xiang)ca”、“助磁法ab” 、“助磁法ab” 、“助磁法ab” “三相(xiang)(xiang)同測(ce)Y”和“三相(xiang)(xiang)同測(ce)△”。

測(ce)試(shi)溫度:設置(zhi)所測(ce)試(shi)品的當前油(you)溫,油(you)溫數值(zhi)從-99℃~+99℃,此數值(zhi)關系電阻折算值(zhi)。

折(zhe)(zhe)算溫(wen)度:設置在當前油(you)溫(wen)下(xia)測得的(de)(de)電阻值需(xu)要折(zhe)(zhe)算的(de)(de)溫(wen)度值,折(zhe)(zhe)算溫(wen)度數值從0℃~+255℃,此數值關系電阻折(zhe)(zhe)算值。

試(shi)(shi)品編號:設置本(ben)次試(shi)(shi)驗的試(shi)(shi)品編號。

測    試(shi):選擇測試(shi)電流檔位。

參數設(she)置完成后,選中“測試”項后按“確認”鍵開始(shi)測量。

5.3.2.2單相測試(shi)

在“直阻(zu)參(can)數設置”屏(ping)下“測試相別”項中(zhong)選(xuan)擇單(dan)(dan)相相別相后,可進行所選(xuan)相的單(dan)(dan)相測量。例(li),選(xuan)擇測量“AB”相(見圖十)。

充電(dian)完成后,儀(yi)器(qi)自(zi)動進行測量(見(jian)圖十一(yi))。

屏幕中間(jian)顯示(shi)(shi)測量(liang)結果,底部顯示(shi)(shi)可操作菜單:

重新測(ce)試(shi):儀器重新采樣電(dian)流電(dian)壓值進行測(ce)試(shi)。

結果(guo)打印:將測(ce)試結果(guo)進行(xing)打印。

結果(guo)存(cun)(cun)儲:將(jiang)測試結果(guo)存(cun)(cun)儲到本機或存(cun)(cun)儲到優盤。

 “左右(you)”鍵選擇菜(cai)單項(xiang),“確認”鍵執行當(dang)前選項(xiang)。

此時按“取消”鍵(jian),儀器將停(ting)止測試(shi),并開始放電(見圖十二)。

放電(dian)完成后,儀器自動返回直(zhi)阻參數設置屏。

5.3.2.3三相Yn測(ce)試

在(zai)“直阻(zu)參數設(she)置”屏下“測試相(xiang)別(bie)”項中選擇“三(san)(san)(san)相(xiang)同測Yn”測試相(xiang)后,可進行Yn型繞組的(de)三(san)(san)(san)相(xiang)測量,在(zai)進行三(san)(san)(san)相(xiang)測量前需選擇是否啟用中性點校正功能(見圖十三(san)(san)(san))。

如選擇(ze)啟(qi)用中性點校(xiao)正功能,儀器將(jiang)先(xian)測(ce)(ce)量(liang)(liang)單(dan)(dan)相(xiang)(xiang)AO數(shu)(shu)據暫(zan)存,然后(hou)再進行(xing)三(san)相(xiang)(xiang)測(ce)(ce)量(liang)(liang),*后(hou)使用暫(zan)存的AO數(shu)(shu)據進行(xing)中性點校(xiao)正,使三(san)相(xiang)(xiang)測(ce)(ce)量(liang)(liang)數(shu)(shu)據更接(jie)(jie)近單(dan)(dan)相(xiang)(xiang)法(fa)測(ce)(ce)量(liang)(liang)的數(shu)(shu)據;如不啟(qi)用該(gai)功能,儀器將(jiang)直(zhi)接(jie)(jie)進行(xing)三(san)相(xiang)(xiang)測(ce)(ce)量(liang)(liang),速度(du)更快,只是數(shu)(shu)據與單(dan)(dan)相(xiang)(xiang)測(ce)(ce)量(liang)(liang)數(shu)(shu)據差異稍大(da)一些,但是對(dui)于三(san)相(xiang)(xiang)不平衡(heng)率影(ying)響(xiang)微(wei)乎(hu)其微(wei)。

本(ben)說(shuo)明(ming)(ming)書只以(yi)帶中(zhong)性點(dian)校正功能(neng)的(de)測(ce)(ce)試方(fang)法(fa)加以(yi)說(shuo)明(ming)(ming),不(bu)帶中(zhong)性點(dian)校正功能(neng)只需跳過單(dan)相測(ce)(ce)量步驟(zou)即可。

三(san)相(xiang)測(ce)(ce)量將先(xian)測(ce)(ce)量出單(dan)相(xiang)AO阻值(zhi),然后自動進行三(san)相(xiang)充電計算三(san)相(xiang)電阻值(zhi),這樣(yang)可以解決三(san)相(xiang)同時(shi)測(ce)(ce)試時(shi)中性(xing)點引出線電阻不能測(ce)(ce)試的問題,使測(ce)(ce)試數據更接(jie)近單(dan)相(xiang)測(ce)(ce)試值(zhi)。

單相AO阻(zu)值(zhi)測試完成(cheng)后(hou),儀(yi)器(qi)自動單相放(fang)電(dian),放(fang)電(dian)完成(cheng)后(hou)自動進行三(san)相充電(dian)并計算三(san)相電(dian)阻(zu)值(zhi)(見圖十五)。

當三相(xiang)不平(ping)衡率穩定后可對變(bian)壓器的有載(zai)分接開關進行調檔操(cao)作(zuo),儀器將自動(dong)跟蹤測(ce)試調檔后的電阻值,上、下鍵可修改分接位。

重新測試:儀(yi)器重新采樣電流(liu)電壓值(zhi)進(jin)行測試。

結果打印(yin):將測(ce)試(shi)結果進行打印(yin)。

結(jie)(jie)果(guo)存儲(chu)(chu):將測(ce)試結(jie)(jie)果(guo)存儲(chu)(chu)到(dao)本機或存儲(chu)(chu)到(dao)優盤。

 “左(zuo)右(you)”鍵(jian)選(xuan)(xuan)擇菜(cai)單項,“確認”鍵(jian)執行當(dang)前選(xuan)(xuan)項。

按“取消”鍵(jian),儀器將停(ting)止測試,并開始(shi)放電(見圖十六)。

5.3.2.4三相(xiang)Y、△測(ce)試(shi)

在“直阻(zu)參數設置”屏下“測試(shi)相(xiang)別”項中選擇“三(san)(san)相(xiang)同測Y”或(huo)“三(san)(san)相(xiang)同測△”測試(shi)相(xiang)后(hou),可進行Y型繞組(zu)和△繞組(zu)的(de)三(san)(san)相(xiang)自動測量(liang)。兩種繞組(zu),測試(shi)操作過程相(xiang)同,現以Y型繞組(zu)舉例說明,如圖十七

在此界面,用戶可(ke)按“確(que)認”鍵切換手動模式(shi)(shi)和自動模式(shi)(shi)。在自動模式(shi)(shi)下,儀(yi)器(qi)自動判斷阻值穩定,停止放(fang)電(dian),進(jin)行下一(yi)相(xiang)(xiang)測試;在手動模式(shi)(shi)下,需(xu)用戶自己判斷阻值穩定,選擇測試下一(yi)相(xiang)(xiang)。當三相(xiang)(xiang)阻值測試完畢后,儀(yi)器(qi)自動計(ji)算出三相(xiang)(xiang)不平衡率(見圖十(shi)八)。

重新測試(shi):儀器將刪除(chu)數據,重新進(jin)行(xing)測量。

結果打印:將測試結果進行打印。

結果(guo)存儲(chu):將測試結果(guo)存儲(chu)到本機或存儲(chu)到優盤。

 “左(zuo)右”鍵選(xuan)擇菜單(dan)項,“確(que)認”鍵執行當前選(xuan)項。按“取消”鍵,返回(hui)上一屏(ping)。

5.3.3 存儲查詢(xun)

在“主(zhu)菜單”屏(ping)下選(xuan)中“存儲查詢(xun)”選(xuan)項(xiang),按“確(que)認”鍵(jian)進入“存儲查詢(xun)選(xuan)擇”屏(ping)(見(jian)圖十九(jiu))。

在“存(cun)儲(chu)(chu)查(cha)詢(xun)選擇(ze)”屏下(xia)選中“變(bian)比(bi)測(ce)試查(cha)詢(xun)”選項,按“確認”鍵進入“變(bian)比(bi)測(ce)試查(cha)詢(xun)”屏(見圖二(er)十)。如(ru)果沒有(you)存(cun)儲(chu)(chu)數據,會(hui)提示“無存(cun)儲(chu)(chu)記錄(lu)!!”

在“存(cun)儲查(cha)(cha)詢選擇”屏下選中“直阻(zu)測試查(cha)(cha)詢”選項(xiang),按(an)“確認”鍵進入“直阻(zu)測試查(cha)(cha)詢”屏(見圖二十一)。如果沒(mei)有(you)存(cun)儲數(shu)據,會提示“無存(cun)儲記錄!!”

屏幕(mu)上(shang)部和中(zhong)部顯(xian)示存(cun)儲的(de)數(shu)據(ju)信息(xi),屏幕(mu)底部顯(xian)示存(cun)儲的(de)查詢索引:

存(cun)儲(chu)001/020:001表(biao)示(shi)當前查(cha)詢的(de)存(cun)儲(chu)數據的(de)位置,即(ji)第幾條存(cun)儲(chu)記(ji)(ji)錄,其中001表(biao)示(shi)*新的(de)存(cun)儲(chu)記(ji)(ji)錄。020表(biao)示(shi)共存(cun)儲(chu)了多少條測試記(ji)(ji)錄。

在有存(cun)儲數據的情(qing)況下(xia),在“存(cun)儲查詢”屏下(xia)按(an)“左右(you)”鍵進行不同存(cun)儲信息的查詢,按(an)“確(que)認”鍵彈(dan)出(chu)功能菜(cai)單(dan),可進行“存(cun)儲打印”、“轉存(cun)優盤”操作。

存儲(chu)打(da)印(yin):將當前查詢的存儲(chu)數據進行打(da)印(yin)。

轉(zhuan)存(cun)優盤:將當(dang)前查詢的存(cun)儲數據轉(zhuan)存(cun)到外接優盤。

5.3.4 時鐘設(she)置

在“主(zhu)菜(cai)單”屏下選中“時鐘(zhong)設置”選項,按“確認”鍵進入(ru)“時鐘(zhong)設置”屏(見圖二十二)。

在“時鐘設置”屏(ping)下按(an)“左右(you)”鍵(jian)對要(yao)修(xiu)改項進行選擇,按(an)“上下”鍵(jian)修(xiu)改所選項,按(an)“確認”鍵(jian)保存當前(qian)設置并返回(hui)“主菜單(dan)”屏(ping),按(an)“取消”鍵(jian)放棄(qi)當前(qian)設置并返回(hui)“主菜單(dan)”屏(ping)。(注:本時鐘設置功能可根據閏年自動計(ji)算(suan)二月份的天數,并能根據所設置日期(qi)自動計(ji)算(suan)出(chu)星(xing)期(qi)幾。)

5.3.5 裝置(zhi)信(xin)息

此菜單只是介紹本裝置的一(yi)些基本信息。

5.3.6 廠家設置

此(ci)項(xiang)為廠家設置項(xiang),需(xu)要密碼,用戶不能設置。

6 注意事項

6.1 變(bian)比測試

6.1.1 對(dui)于具(ju)有多個(ge)分(fen)(fen)接(jie)位的(de)變壓(ya)器,輸入額(e)定(ding)高、低(di)壓(ya)電壓(ya)值、分(fen)(fen)接(jie)間(jian)距(ju)、額(e)定(ding)檔位,是為了使測試結果可以(yi)自動(dong)計算出(chu)誤差值,以(yi)及分(fen)(fen)接(jie)開(kai)關所(suo)處的(de)分(fen)(fen)接(jie)位。如果上述參數輸入正確,則測試各個(ge)分(fen)(fen)接(jie)位時都可以(yi)自動(dong)計算出(chu)該分(fen)(fen)接(jie)位的(de)變比誤差值以(yi)及該分(fen)(fen)接(jie)位的(de)具(ju)體位置,不必再做數據改動(dong)。

6.1.2 有載分接開關19檔的變壓(ya)器,若9、10、11分接是(shi)同一個值,儀器輸(shu)入(ru)額定分接位(wei)時(shi)應輸(shu)入(ru)9,此時(shi)12分接位(wei)以后,儀器顯示分接位(wei)置(zhi)比實際位(wei)置(zhi)小2。

6.1.3 本儀器(qi)分(fen)(fen)接位置(zhi)的設置(zhi)按高(gao)壓(ya)(ya)(ya)側調(diao)壓(ya)(ya)(ya)設計,是假設1分(fen)(fen)接為*高(gao)電壓(ya)(ya)(ya)擋位,如(ru)果電壓(ya)(ya)(ya)反向(xiang)設計或(huo)分(fen)(fen)接開(kai)關在低壓(ya)(ya)(ya)側的變壓(ya)(ya)(ya)器(qi),顯(xian)示分(fen)(fen)接位置(zhi)和實(shi)際分(fen)(fen)接位置(zhi)倒置(zhi)。

6.1.4 三(san)相(xiang)變(bian)壓(ya)器銘牌(pai)上的(de)變(bian)比(bi)(bi)是指不(bu)同(tong)(tong)電壓(ya)繞組(zu)的(de)線(xian)(xian)(xian)電壓(ya)之比(bi)(bi),因此(ci),不(bu)同(tong)(tong)接(jie)(jie)(jie)線(xian)(xian)(xian)方(fang)式的(de)變(bian)壓(ya)器,其變(bian)比(bi)(bi)與匝(za)數比(bi)(bi)有如下關系(xi):一次(ci)、二(er)次(ci)側(ce)接(jie)(jie)(jie)線(xian)(xian)(xian)相(xiang)同(tong)(tong)的(de)三(san)相(xiang)變(bian)壓(ya)器的(de)電壓(ya)比(bi)(bi)等于(yu)(yu)匝(za)數比(bi)(bi);一次(ci)側(ce)、二(er)次(ci)側(ce)接(jie)(jie)(jie)線(xian)(xian)(xian)不(bu)同(tong)(tong)時,Y-d接(jie)(jie)(jie)線(xian)(xian)(xian)的(de)匝(za)比(bi)(bi)值(zhi)等于(yu)(yu)變(bian)比(bi)(bi)值(zhi)除以,D-y接(jie)(jie)(jie)線(xian)(xian)(xian)的(de)匝(za)比(bi)(bi)值(zhi)等于(yu)(yu)變(bian)比(bi)(bi)值(zhi)乘(cheng)以。

6.2直阻測試

6.2.1在(zai)無載調壓繞組,不允許在(zai)測(ce)試過程中或未放(fang)完電時(shi)切換無載分接(jie)開關(guan)。

6.2.2在測試過程中或(huo)放電過程中不允許拆除測試線和切斷AC220V電源。

6.2.3在高壓(ya)(ya)端子測試過程中(zhong),變壓(ya)(ya)器中(zhong)壓(ya)(ya)和低壓(ya)(ya)端必須(xu)開路。

7 售后服務

7.1 本公司產品隨機攜帶產品保修(xiu)單(dan),訂購產品交貨時,請當場檢驗并填好保修(xiu)單(dan)。

7.2 自購機之日(ri)起,憑(ping)保(bao)修(xiu)(xiu)(xiu)單保(bao)修(xiu)(xiu)(xiu)兩年,終身維護。在(zai)保(bao)修(xiu)(xiu)(xiu)期內,維修(xiu)(xiu)(xiu)不收維修(xiu)(xiu)(xiu)費;保(bao)修(xiu)(xiu)(xiu)期外,維修(xiu)(xiu)(xiu)調試(shi)收取適當費用(yong)。

7.3 屬下列情況之一者不予保修:

7.3.1 用(yong)戶對(dui)產品有(you)自行拆卸(xie)或(huo)對(dui)產品工藝結構有(you)人為(wei)改變。

7.3.2 因用戶保管或使用不當(dang)造成(cheng)產品的嚴重損壞。

7.3.3 屬于(yu)用戶(hu)其它原因造成的損壞(huai)。